Repository navigation
Expand file tree
/
Copy pathcases.csv
More file actions
We can make this file beautiful and searchable if this error is corrected: It looks like row 306 should actually have 5 columns, instead of 4 in line 305.
408 lines (408 loc) · 55.8 KB
/
Copy pathcases.csv
File metadata and controls
408 lines (408 loc) · 55.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
,Description,Choices,Default Value,Ref
timetype,Sequential or Intertemporal,seq; int; win,seq,
ignore,"0=run this case, 1=ignore this case",0; 1,0,
AWS,Switch for when running on AWS,0; 1,0,
yearset,"_-delimited list of years to model OR bash-formatted year ranges (start..end..step). For example, 2010_2015_2020..2035..3_2040..2050..5 means: 2010, 2015, then 2020 through 2035 in 3-year steps, then 2040 through 2050 in 5-year steps. startyear will be the first year in the list. Truncated at endyear.",N/A,2010..2050..5,
endyear,Last year to be modeled,N/A,2050,
windows_suffix,Set of windows that are modeled,default; step5; step10; 2100,default,
solver,Solver for GAMS to use,CPLEX; gurobi,CPLEX,
distpvscen,Setting for distpv scenario (see inputs\dgen_model_inputs),N/A,stscen2023_mid_case,
calc_csp_cc,Switch to turn on CSP capacity credit calculations,0; 1,0,
plantchar_battery,Battery cost and performance inputs (inputs\plant_characteristics\{plantchar_battery}.csv). The options for plantchar_battery start with 'battery_' and the switch should be set to the entire file name (ex: battery_ATB_2024_advanced),battery_ATB_(2023|2024)_(conservative|moderate|advanced),battery_ATB_2024_moderate,
plantchar_beccs,BECCS cost and performance inputs (inputs\plant_characteristics\{plantchar_beccs}.csv) The options for plantchar_beccs start with 'beccs_' and the switch should be set to the entire file name (ex: beccs_reference),(beccs_BVRE_2021_(high|mid|low)|beccs_(reference|lowcost)),beccs_reference,
plantchar_biopower,Biopower generators cost and performance characteristics (inputs\plant_characteristics\{plantchar_biopower}.csv). Options start with 'biopower_' and the switch should be set to the entire file name (ex: biopower_ATB_2024_moderate),biopower_ATB_(2024)_(moderate),biopower_ATB_2024_moderate,
plantchar_coal_ccs,Coal CCS generators cost and performance characteristics (inputs\plant_characteristics\{plantchar_coal_ccs}.csv). Options start with 'coal-ccs_' and the switch should be set to the entire file name (ex: coal-ccs_ATB_2024_moderate),coal-ccs_ATB_(2024)_(conservative|moderate|advanced),coal-ccs_ATB_2024_moderate,
plantchar_coal,Coal generators cost and performance characteristics (inputs\plant_characteristics\{plantchar_coal}.csv). Options start with 'coal_' and the switch should be set to the entire file name (ex: coal_ATB_2024_moderate),coal_ATB_(2024)_(moderate),coal_ATB_2024_moderate,
plantchar_csp,CSP cost and performance characteristics (inputs\plant_characteristics\{plantchar_csp}.csv). The options for plantchar_csp start with 'csp_' and the switch should be set to the entire file name (ex: csp_ATB_2024_advanced),csp_ATB_(2023|2024)_(conservative|moderate|advanced),csp_ATB_2024_moderate,
plantchar_fuelcell,Fuel cell cost and performance characteristics (inputs\plant_characteristics\{plantchar_fuelcell}.csv). The options for plantchar_fuelcell start with 'fuelcell_' and the switch should be set to the entire file name (ex: fuelcell_ATB_2024_advanced),fuelcell_ATB_2024_(moderate|advanced),fuelcell_ATB_2024_moderate,
plantchar_gas_ccs,Natural gas CCS generator cost and performance characteristics (inputs\plant_characteristics\{plantchar_gas_ccs}.csv). Options start with 'gas-ccs' and the switch should be set to the entire file name (ex: gas-ccs_ATB_2024_moderate),gas-ccs_ATB_(2024)_(conservative|moderate|advanced),gas-ccs_ATB_2024_moderate,
plantchar_gas,Natural gas generator cost and performance characteristics (inputs\plant_characteristics\{plantchar_gas}.csv). Options start with 'gas_' and the switch should be set to the entire file name (ex: gas_ATB_2024_moderate),gas_ATB_(2024)_(moderate),gas_ATB_2024_moderate,
plantchar_geo,Geothermal cost setting (inputs\plant_characteristics\{plantchar_geo}.csv).The options for plantchar_geo start with 'geo_' and the switch should be set to the entire file name (ex: geo_ATB_2023_conservative),geo_ATB_(2023|2024)_(conservative|moderate|advanced),geo_ATB_2024_moderate,
plantchar_h2fuelcell,H2 fuel cell cost and performance characteristics (inputs\plant_characteristics\{plantchar_h2fuelcell}.csv). The options for plantchar_h2fuelcell start with 'h2fuelcell_' and the switch should be set to the entire file name (ex: h2fuelcell_moderate),h2fuelcell_(conservative|moderate|advanced),h2fuelcell_moderate,
plantchar_h2combustion,H2-CT/CC cost and performance inputs (inputs/plant_characteristics/{h2combustionscen}.csv). The options for h2combustionscen start with 'h2-combustion_' and the switch should be set to the entire file name (ex: h2-combustion_ATB_2023),h2-combustion_ATB_(2024),h2-combustion_ATB_2024,
plantchar_hydro,Hydropower cost inputs (inputs/plant_characteristics/{plantchar_hydro}.csv). The options for plantchar_hydro start with 'hydro_' and the switch should be set to the entire file name (ex: hydro_ATB_2019_low),hydro_ATB_2019_(constant|mid|low),hydro_ATB_2019_mid,
plantchar_nuclear_smr,Small modular reactor (SMR) cost and performance characteristics (inputs\plant_characteristics\{plantchar_nuclear_smr}.csv). Options start with 'nuclear_smr' and the switch should be set to the entire file name (ex: nuclear-smr_ATB_2024_moderate),nuclear-smr_ATB_(2024)_(conservative|moderate|advanced),nuclear-smr_ATB_2024_moderate,
plantchar_nuclear,Large nuclear cost and performance characteristics (inputs\plant_characteristics\{plantchar_nuclear}.csv). Options start with 'nuclear_' and the switch should be set to the entire file name (ex: nuclear_ATB_2024_moderate),nuclear_ATB_(2024)_(conservative|moderate|advanced),nuclear_ATB_2024_moderate,
plantchar_ofswind,Offshore wind cost and performance inputs (inputs/plant_characteristics/{plantchar_ofswind}.csv). The options for plantchar_ofswind start with 'ofs-wind_' and the switch should be set to the entire file name (ex: ofs-wind_ATB_2023_advanced),ofs-wind_ATB_(2023|2024)_(conservative|moderate|advanced|moderate_noFloating),ofs-wind_ATB_2024_moderate,
plantchar_onswind,Onshore wind cost and performance inputs (inputs/plant_characteristics/{plantchar_onswind}.csv). The options for plantchar_onswind start with 'ons-wind_' and the switch should be set to the entire file name (ex: ons-wind_ATB_2023_advanced).,ons-wind_ATB_(2023|2024)_(conservative|moderate|advanced),ons-wind_ATB_2024_moderate,
plantchar_other,Cost and performance characteristics for lfill-gas and o-g-s (inputs\plant_characteristics\{plantchar_other}.csv). Options start with 'other_' and the switch should be set to the entire file name (ex: other_plantchar)',other_plantchar,other_plantchar,
plantchar_upv,UPV cost and performance inputs (inputs/plant_characteristics/{plantchar_upv}.csv). The options for plantchar_upv start with 'upv_' and the switch should be set to the entire file name (ex: upv_ATB_2023_advanced).,upv_ATB_(2023|2024)_(conservative|moderate|advanced),upv_ATB_2024_moderate,
ccsflexscen,"Flexible CCS scenario (inputs\plant_characteristics\{ccsflexscen}_cost/perf.csv).The options for ccsflexscen start with 'ccsflex_' and the switch should be set to the file name, dropping '_cost' or '_perf' (ex: ccsflex_ATB_2020)",ccsflex_ATB_2020,ccsflex_ATB_2020,
ccs_upgrade_cost_case,case in upgrade_cost_ccs_coal and upgrade_cost_ccs_gas to use for ccs retrofit costs,atb22_1p2_moderate; atb22_1p2_advanced,atb22_1p2_moderate,
coalscen,"Coal price scenario (inputs\fuelprices\{coalscen}.csv). The options for coalscen start with 'coal_' and the switch should be set to the file name, dropping 'coal' (ex: AEO_2025_reference)",AEO_2025_reference; AEO_2026_baseline; AEO_2026_altelec,AEO_2026_altelec,
demandscen,Demand scenario (see inputs\load),N/A,AEO_2026_baseline,
dr_shedscen,DR shed scenario,demo_data_January_2025,demo_data_January_2025,
evmcscen,EVMC scenario for load and supply curve and flexibility,Baseline,Baseline,
geodiscov,Annual discover rates for new geothermal sites,BAU; TI,BAU,
geohydrosupplycurve,Geohydro Supply Curve,ATB_2023,ATB_2023,
egssupplycurve,EGS Supply Curve,ATB_2023; reV,reV,
egsnearfieldsupplycurve,EGS (near field) Supply Curve,ATB_2023,ATB_2023,
ngscen,Natural gas price inputs,^AEO_(2025_(HOG|reference|LOG)|2026_(HOG|baseline|LOG))$,AEO_2026_baseline,
pshsupplycurve,PSH Supply Curve,(8|10|12)hr_(limited|reference|open),8hr_reference,
pvbscen,PVB cost-sharing scenario,benchmark2020,benchmark2020,
dacscen,Electrical DAC cost and performance inputs (see inputs/consume/[dacscen].csv starting with 'dac_elec_').,BVRE_2021_(high|mid|low),BVRE_2021_mid,
h2combustionfuelscen,H2-CT/CC Fuel Price Scenarios (only used if endogenous H2 production is turned off),10; reference; 30,reference,
upgradescen,Exogenous upgrade capital cost specification (see inputs\upgrades). 'default' calculates cost using diff between from- and to- tech,N/A,default,
nukeretscen,Nuclear retirement scenario (years from plant online year),int,80,
supplycurve,Wind and Solar Supply Curves,default; 0; naris; 2018,default,
uraniumscen,Uranium price scenario,AEO_2025_reference; AEO_2026_baseline,AEO_2026_baseline,
GSw_Region,Specify {column of hierarchy.csv}/{period-delimited entries to keep from that column},N/A,country/USA,
GSw_ZoneSet,Set of geospatial zones to use as balancing areas (described in inputs/zones/README.md),^(z48|z54|z70|z90|z132|z134|z3109|UTcounty|PJMcounty)$,z90,
capcredit_hierarchy_level,Select level at which to aggregate net load for capacity-credit calculation,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,transreg,
construction_schedules_suffix,File suffix for construction schedules,default,default,
construction_times_suffix,File suffix for construction times by technology,default,default,
degrade_suffix,File suffix for annual degredation by technology,default,default,
depreciation_schedules_suffix,File suffix for depreciation schedules,default,default,
financials_sys_suffix,File suffix for the system-wide system discount rate,ATB(2023|2024),ATB2024,
financials_tech_suffix,File suffix for technology-specific financial assumptions (see inputs\financials_tech),ATB(2023|2023_CRP20|2024),ATB2024,
financials_trans_suffix,File suffix for transmission financial assumptions,default; 30ITC_0pen_2022_2031,default,
FINITO,Switch to enable running linked ReEDS-FINITO model (mapped to GSw_FINITO_Link),0; 1,0,
FINITO_cases_file,"Filename suffix of the FINITO cases file that includes the scenarios to be run (e.g., 'linked' for cases_linked.csv)",N/A,linked,
FINITO_case,FINITO case for this run; must be a column in the files specified by FINITO_cases_file. Use 'same' if the ReEDS run name matches the FINITO case name,N/A,same,
FINITO_dir,Directory with cloned FINITO repository,N/A,{reeds_path}/../FINITO,
FINITO_dollaryear,[$] real dollar year for FINITO; do not change until all inputs and reporting are adjusted appropriately,2018,2018,
FINITO_first_year,First year when the FINITO module is to be run,N/A,2018,
incentives_suffix,File suffix for incentive definition,ira; obbba; obbba_conservative; annual; biennial; ira_45q_45v_extension; none,obbba,
inflation_suffix,File suffix for historical inflation schedule,default,default,
ivt_suffix,File suffix for ivt csv file,default; small; step,default,
reg_cap_cost_diff_suffix,File suffix for regional capital cost differences,default,default,
techs_suffix,File suffix for master list of technologies,default; subsetForTesting,default,
dollar_year,DO NOT CHANGE FROM 2004 UNTIL ALL FINANCIAL INPUTS HAVE DOLLAR YEAR ADJUSTMENT - Real dollar year for model to calculate and report,2004,2004,
sys_eval_years,Number of years that the model evaluates investments on,int,30,
numhintage,"number of hintage bins. Enter 'unit' for unit level bins. Enter 'group' to group by unique technology, region, and heatrate combinations",int,6,
numbins_windons,Number of interconnection supply curve bins for onshore wind,int,10,
numbins_windofs,Number of interconnection supply curve bins for offshore wind; options are 5 and 1300 (for individual sites lite),int,5,
numbins_upv,Number of interconnection supply curve bins for upv,int,40,
numbins_csp,Number of interconnection supply curve bins for csp,int,5,
numbins_geohydro_allkm,Number of interconnection supply curve bins for hydrothermal geothermal,int,10,
numbins_egs_allkm,Number of interconnection supply curve bins for deep enhanced geothermal,int,10,
numbins_psh, Number of interconnection supply curve bins for pumped storage hydropower,int,15,
mindev,minimum deviation for a hintage to qualify for a new bin,int,50,
unitdata,"Unit Database: ""EIA-NEMS"" for NEMS",EIA-NEMS,EIA-NEMS,
marg_vre_mw,MW for marginal VRE curt/cc calcs,N/A,1000,
marg_stor_mw,MW for marginal storage capacity credit,N/A,100,
marg_evmc_mw,MW for marginal electric vehicle managed charging (EVMC) capacity credit,N/A,100,
GSw_AnnualCap,CO2/CO2e emission cap. Turn off cap (0) or turn on CO2 only cap (1) or turn on CO2e cap (2) or include H2 leakage in CO2e cap (3) ,0; 1; 2; 3,0,
GSw_AnnualCapScen,Scenario for CO2 cap pathway (see inputs\emission_constraints\co2_cap.csv),N/A,default,
GSw_AVG_iter,Select method for choosing which iterations are used for CC/curt calculations,0; 1,1,
GSw_BankBorrowCap,Turn on/off CO2 cap with banking and borrowing,0; 1,0,
GSw_BatteryMandate,Turn on/off battery mandate constraint,0; 1,1,
GSw_BECCS,Turn on/off BECCS technology,0; 1,1,
GSw_BinOM,Turn on/off binned FOM and VOM for each historical binned vintage,0; 1,1,
GSw_Biopower,Turn on/off biopower,0; 1,1,
GSw_BioSupply,Multiplier to adjust total biomass supply,N/A,1,
GSw_BioTransportCost,Biomass collection and transport costs ($2004 per dry ton),N/A,22,
GSw_calc_powfrac,Compute powfrac in report.gms and powfrac_calc.gms - dramatically increases calculation times with hourly resolution,0; 1,0,
GSw_Canada,"Turn canada off [0], or use flexible (dispatchable-hydro-like) representation [1]",0; 1,1,
GSw_CarbTax,Turn on/off CO2 tax,0; 1,0,
GSw_CarbTaxOption,Choose the co2_tax input csv file (see inputs\emission_constraints),,default,
GSw_CCS,Turn on/off all inflexible CCS,0; 1,1,
GSw_CCS_NotRecTech,Turn on/off removal of CCS techs from CES eligibility,0; 1,0,
GSw_CCS_Rate_New_mod,fractional CO2 capture rate of new CCS_mod capacity,float,0.95,
GSw_CCS_Rate_New_max,fractional CO2 capture rate of new CCS_max capacity,float,0.99,
GSw_CCS_Rate_Upgrade_mod,fractional CO2 capture rate of retrofit CCS_mod capacity,float,0.9,
GSw_CCS_Rate_Upgrade_max,fractional CO2 capture rate of retrofit CCS_max capacity,float,0.99,
GSw_CCSFLEX_BYP,Turn on/off all Flexible CCS with Bypass,0; 1,0,
GSw_CCSFLEX_cap_max,CCS maximum capture,float,90,
GSw_CCSFLEX_cost_mult,CCS capital cost multiplier,float,1,
GSw_CCSFLEX_DAC,Turn on/off all Flexible CCS with Direct Air Capture,0; 1,0,
GSw_CCSFLEX_STO,Turn on/off all Flexible CCS with Storage,0; 1,0,
GSw_CCSFLEX_STO_LEVEL,Turn on/off explicit tracking of flexible CCS storge level (1=explicit; 0=implicit),0; 1,1,
GSw_CCS_NoRetire,Switch to prevent coal and gas from turning off CCS equipment after upgrading. 0 = can turn CCS equipment off. 1 = must keep CCS equipment on.,0; 1,0,
GSw_CheckInputs,Switch to turn on/off inputs checking,0; 1,1,
climateloc,Directory for climate scenarios (change to qnap/CIRA_Inputs_R2 to use scenarios not included in inputs/climate),N/A,inputs/climate,
climatescen,Climate scenario for climate impacts,HadGEM2-ES_rcp45_AT; HadGEM2-ES_rcp85_AT; HadGEM2-ES_RCP2p6; HadGEM2-ES_RCP4p5; HadGEM2-ES_RCP8p5; GFDL-ESM2M_RCP4p5_WM; IPSL-CM5A-LR_RCP8p5_WM,HadGEM2-ES_rcp45_AT,
GSw_Clean_Air_Act,"Turn on/off the provisions under the Clean Air Act, Section 111, which regulate the emissions from existing coal plants and new gas plants.",0; 1,0,
GSw_ClimateHeuristics,Select scenario for a variety of climate heuristics,none; 2025_2050_linear,none,
GSw_ClimateHydro,Turn on/off climate impacts on hydropower,0; 1,0,
GSw_ClimateStartYear,Year in which to start applying climate impacts,N/A,2022,
GSw_ClimateWater,Turn on/off climate impacts on cooling water,0; 1,0,
GSw_CO2_Storage,"Include costs from CO2 transport and storage. 0 includes no costs, positive values applied as $ per metric ton to captured CO2. Enter in $2004. Suggested range of values based on NETL 2019 report : 11 (base), 7 (low), 26 (high)",N/A,11,
GSw_CO2_pipeline_cost,Set capex cost for CO2 Pipeline. 2004$/(tonne-mi)/hr. Suggested value: 2257,N/A,2257,
GSw_CO2_pipeline_fom,Set FOM cost for CO2 Pipeline. 2004$/(tonne-mi)/hr-yr. Suggested value: 60,N/A,60,
GSw_CO2_spurline_cost,Set capex cost for CO2 Spurline. 2004$/(tonne-mi)/hr. Suggested value: 2257,N/A,2257,
GSw_CO2_spurline_fom,Set FOM cost for CO2 Spurline. 2004$/(tonne-mi)/hr-yr. Suggested value: 60,N/A,60,
GSw_CO2_Detail,Switch to enable detailed representation CO2 transportation and storage,0; 1,0,
GSw_CO2_CostAdj,multiplier for co2 infrastructure when Sw_CO2_Detail = 1,float,1,
GSw_CO2_BEC,"Break even cost capacity factor assignment. Must be a suffix to ""bec_"" in the columns of co2_site_char.csv",N/A,70,
GSw_CoalIGCC,Turn on/off COAL IGCC,0; 1,1,
GSw_CoalNew,Turn on/off coal new,0; 1,1,
GSw_CofireNew,Turn on/off cofire-new,0; 1,0,
GSw_CoolingTechMults,Turn on/off to enable cooling tech cost/performance multipliers,0; 1,1,
GSw_CSAPR,Turn on/off the CSAPR emissions regulation,0; 1,1,
GSw_CSP,Turn on/off CSP [0=no CSP; 1=1 CSP tech; 2=2 CSP techs],0,0,
GSw_CSPRemoveLow, Remove the lowest quality CSP resource [0=do not remove; 1=remove],0; 1,1,
GSw_CSP_Types,'_'-delimited CSP types to include (i.e. 1 or 1_2 or 1_2_3),(1|1_2|1_2_3),1,
GSw_DAC,"Turn on or off the representation of direct air capture [0 = off, 1 = on with projection specified by dacscen]",0; 1,0,
GSw_DAC_Gas,"Turn on or off the representation of gas fueled direct air capture [0 = off, 1 = projection specified with GSw_DAC_Gas_Case]",0; 1,0,
GSw_DAC_Gas_Case,DAC gas parameterization case (See inputs/consume/dac_gas_[GSw_DAC_Gas_Case].csv),BVRE_2021_(high|mid|low),BVRE_2021_mid,
GSw_distpv,Turn on/off distpv,0;1,1,
GSw_DRShed, switch to turn on/off demand response shed resource,0;1,0,
GSw_EFS_Flex,Switch for turning EFS load flexibility on or off,0,0,
GSw_EFS2_FlexCase,"Case used for electrification flex_type - format is {1}_{2}, where 1 in [EFS_REFERENCE, EFS_MEDIUM, EFS_HIGH, EFS_Clean2035] and 2 in [Baseflex, Currentflex, Enhancedflex, Uberflex1, Uberflex2]",N/A,EFS_MEDIUM_EnhancedflexStretch2046,
GSw_EmploymentFactor,Source for employment factor data - see inputs/employment/README.md for descriptions,^(jedi|mayfield|rutovitz|ram)$,jedi,
GSw_EVMC,Turn on adoptable EV managed charging,0; 1,0,
GSw_FakeData,Use fake capacity factor profiles (for TESTING ONLY when you do not want to download the real CF data),^[0-1]$,0,
GSw_ForcePrescription,Turn on/off forced prescriptions - turning off will allow unlimited but not free builds in historical years,0; 1,1,
GSw_GasFuelCell,Turn on/off natural gas fuel cell (ng-fuel-cell) as a technology option,0; 1,0,
GSw_FutureHydCF_RepYears,_-delimited years of historical hydro plant data from which to calculate capacity factors representing future hydro,N/A,2007_2008_2009_2010_2011_2012_2013_2016_2017_2018_2019_2020_2021_2022,
GSw_GasCurve,"Select natural gas supply curve (0 = cendiv, 1 = national + cendiv, 2 = static, 3 = national)",0; 1; 2; 3,1,
GSw_GasCC_H_1x1,Turn on/off both gas-CC_H_1x1 and gas-CC_H_1x1-CCS_mod/max plant options,0; 1,0,
GSw_GasCC_H_2x1,Turn on/off both gas-CC_H_2x1 and gas-CC_H_2x1-CCS_mod/max plant options,0; 1,0,
GSw_GasCT_Aero,Turn on/off gas-CT_aeroderivative technology option,0; 1,0,
GSw_GasPriceAdjMethod,"Select method for adjusting gas prices (0 = no adjustment, 1 = national wintertime markup, 2 = daily adjustments based on regional temperatures)",0; 1; 2,2,
GSw_GasRegionSmooth,Exponential decay length [km] to use when smoothing regional (census division) gas prices together (if 0 then no smoothing is applied and r:cendiv map is used 1:1),float,150,
GSw_GasSector,Select sector scope of gas curves,electric_sector; energy_sector,electric_sector,
GSw_GenMandate,Turn on/off national Gen Requirement. 2 turns on and applies constraint at busbar.,0; 1; 2,0,
GSw_GenMandateList,Select technology list for national generation standard (see inputs/national_generation/nat_gen_tech_frac.csv),RE; Nuclear; NuclearCCS,RE,
GSw_GenMandateScen,Select trajectory for national generation standard (see inputs/national_generation/gen_mandate_trajectory.csv),N/A,100_2035,
GSw_Geothermal,"Geothermal can be turned off [0], left to the default representation [1], or have an extended representation [2]",0; 1; 2,1,
GSw_gopt,Select opt file to be used,^[1-4]$,1,
GSw_gopt_mga,Select opt file to be used for MGA runs,^[1-4]$,3,
GSw_GrowthAbsCon,Turn on/off absolute growth constraint,0; 1,0,
GSw_GrowthConLastYear,The last year that the growth constraint (GSw_GrowthAbsCon) is applied (if it is turned on),int,2026,
GSw_GrowthPenalties,Turn on/off relative growth penalties,0; 1,0,
GSw_GrowthPenLastYear,The last year that the growth penalty (GSw_GrowthPenalties) is applied (if it is turned on),int,2034,
GSw_GWP,Global warming potential for CH4 and N2O; either a string specifying IPCC report and timeline (like AR6-100 for 100-year value from IPCC AR6) or a string in the format CH4_{value}/N2O_{value} (for example: CH4_29.8/N2O_273) for arbitrary CH4 and N2O values,AR4-100; AR4-20; AR5-100; AR5-20; AR6-100; AR6-20; CH4_\d*\.?\d+\/N2O_\d*\.?\d+,AR6-100,
GSw_H2,Turn on/off the representation of hydrogen supply/demand balance at a national level without storage (1) or at a regional level with storage (2),0; 1; 2,2,
GSw_H2_CompressorLoad,Turn on/off the accounting of electric loads from compressors used to operate the hydrogen transport network, 0; 1,0,
GSw_H2_Demand_Case,H2 demand case as indicated by the column headers in inputs/consume/h2_exogenous_demand.csv,none; BAU; Aggressive; Decarb; Decarb_with_BAU; LTS,none,
GSw_H2FuelCell,Turn on/off H2 fuel cell (h2-fuel-cell) as a technology option,0; 1,0,
GSw_H2_Inputs,Input file suffix for H2 inputs,ref; low,ref,
GSw_H2_IntraReg_Transport,if non-zero specifies the flat cost for intra-ReEDS BA hydrogen transport in 2004$/kg H2 produced. Recommended value is $0.32/kg per https://liftoff.energy.gov/wp-content/uploads/2023/05/20230523-Pathways-to-Commercial-Liftoff-Clean-Hydrogen.pdf pg 15 for transport costs,float,0.32,
GSw_H2_MinStorHours,Minimum H2 storage duration required by zone (only used when GSw_H2=2),N/A,24,
GSw_H2_PTC,"Turn on/off the representation of the hydrogen production tax credit, also known as 45V in the US tax code",0; 1,1,
GSw_H2_SMR,Turn on/off steam methane reforming (SMR) for hydrogen production,0; 1,0,
GSw_H2_StorTimestep,Indicate resolution at which to model H2 storage level: 1=rep period; 2=timeslice,0; 1; 2,1,
GSw_H2_Transport,Indicate whether to allow interregional H2 transport via pipelines (only has an effect if GSw_H2=2),0; 1,0,
GSw_H2_TransportLevel,hierarchy level within which to allow H2 pipelines,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,cendiv,
GSw_H2_TransportUniform,"Option to override H2 storage/transport costs. Value of 0 (default) defers to default tech-specific, time-varying cost settings specified via H2 inputs when GSw_H2=1 or the H2 nework costs when GSw_H2=2. Specify in $2004 per metric ton.",N/A,0,
GSw_H2Combustion,Switch to turn on/off H2CT and H2CC techs,0; 1,1,
GSw_H2Combustionupgrade,Indicate whether to allow gas-CC and gas-CT to upgrade to H2-CT and H2-CC,0; 1,1,
GSw_H2CombinedCycle,Indicate whether to allow H2-CC,0; 1,1,
GSw_H2LeakageScen,Scenarios of H2 leakage rates from upstream and process of producing electricity by technology; scenario name options from emission_constraints/h2_leakage_rate.csv,N/A,Fan_et_al_2022/Med,
GSw_HourlyChunkAggMethod,How to aggregate CF and load within the chunks specified by GSw_HourlyChunkLengthRep (if set to anything other than 'mean' this switch overrides GSw_PRM_StressLoadAggMethod) (ties for mid are broken by the later hour; i.e. for 4-hour chunks and a setting of 'mid' the 3rd hour is used) (if an integer is provided the index starts at 1; i.e. 1 is the 1st hour),(mean|mid|\d),mean,
GSw_HourlyChunkLengthRep,Length of representative-period dispatch timeslices in hours; must be divisible into 24,1; 2; 3; 4; 6; 8; 12; 24,3,
GSw_HourlyChunkLengthStress,Length of stress-period dispatch timeslices in hours; must be divisible into 24,1; 2; 3; 4; 6; 8; 12; 24,3,
GSw_HourlyClusterAlgorithm,Algorithm to use for period selection; options are 'hierarchical' or 'optimized' or 'kmeans' or 'kmedoids' or something containing the substring 'user',N/A,optimized,
GSw_HourlyClusterLoadNorm,Method for normalizing load profile for use in representative period selection: none = no norm; regionmax = each region divided by its max; maxmax = each region divided by max across all regions; maxmin = each region divided by smallest max across all regions; float = maxmin * float,N/A,regionmax,
GSw_HourlyClusterRegionLevel,Indicate the region hierarchy level at which to aggregate RE profiles for clustering,nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; ccreg,transgrp,
GSw_HourlyClusterWeights,/-delimited relative weights for load and RE profiles used in clustering,^load_\d*.?\d+\/upv_\d*.?\d+\/wind-ons_\d*.?\d+\/wind-ofs_\d*.?\d+$,load_1/upv_1/wind-ons_1/wind-ofs_0,
GSw_HourlyClusterYear,Year to use when clustering EFS and/or climate-modified data,N/A,2035,
GSw_HourlyClusterTimestep,Indicate the time resolution to use in clustering algorithm (period=day or wek depending on GSw_HourlyType),hour; period,period,
GSw_HourlyClusterMapMethod,How to map actual periods to representative periods: 'milp' minimizes sum of absolute errors but is slow; 'bestfirst' is orders of magnitude faster when using many weather years in GSw_HourlyWeatherYears,^(milp|bestfirst)$,milp,
GSw_HourlyMinRElevel,Indicate the region hierarchy level at which to include minimum wind and solar capacity factor days (or False to ignore min-wind/solar CF days),false; False; FALSE; r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; ccreg,interconnect,
GSw_HourlyNormProfiles,Indicate whether to normalize load/wind/solar profiles before identification of representative periods,0; 1,0,
GSw_HourlyNumClusters,Number of clusters to create (i.e. number of representative days or weks),int,33,
GSw_HourlyPeakLevel,Indicate the region hierarchy level at which to include peak coincident load days (or False to ignore peaks),false; False; FALSE; r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; ccreg,interconnect,
GSw_HourlyType,Indicate the type of representative period modeled (day=24-hour periods; wek=24×5=120-hour periods; year=8760-hour periods),day; wek; year,day,
GSw_HourlyWeatherYears,_-delimited years from which to construct weather profiles for energy/representative periods,N/A,2012,
GSw_HourlyWindow,Number of timeslices (GSw_HourlyChunkLengthRep hours long) to consider for minloading constraint,int,2,
GSw_HourlyWindowOverlap,Number of overlapping timeslices between adjacent GSw_HourlyWindow,int,1,
GSw_HourlyWrap,Switch to enable wrapping of final hour modeled in each representative period back to the first,0; 1,1,
GSw_HourlyWrapLevel,Indicate whether to wrap storage over full year or over seasons (only used for chronological 8760),season; year,year,
GSw_HybridPlant,"0=Ban all storage, including CSP, 1=Allow CSP, ban all other storage, 2=Allow hybrid plants, excluding CSP, 3=Allow CSP and all other hybrid plants",0; 1; 2; 3,3,
GSw_hydED,Turn on/off other hydro technologies except for hydED,0; 1,1,
GSw_HydroAddPumpDispUpgSwitch,Turn on/off availability of hydro upgrades to add pumping or dispatchability,0; 1,0,
GSw_HydroCapEnerUpgradeType,"1=coupled capacity/energy upgrades, 2=independent capacity/energy upgrades",1; 2,1,
GSw_HydroCostAddDispatch,Cost of hydro upgrade to dispatchable (2004$/MW),N/A,309000,
GSw_HydroCostAddPump,Cost of hydro upgrade to pumped (2004$/MW),N/A,998000,
GSw_HydroCostFracCapUp,Fraction of upgrade cost assigned to capacity (only used if GSw_HydroUpgrade=1),float,0.8,
GSw_HydroCostFracEnerUp,Fraction of upgrade cost assigned to energy (only used if GSw_HydroUpgrade=1),float,0.8,
GSw_HydroPSHDurData,Turn on/off use of regional storage duration for existing PSH fleet,0; 1,1,
GSw_HydroStorInMaxFrac,"max storage_in as fraction of capacity for psh (numerical values apply to all PSH, set to 'data' to use input file)",N/A,data,
GSw_HydroStorInMinLoad,min loading frac for storage_in for psh,N/A,0,
GSw_HydroUpgradeCapMult,multiplier on hydro upgrade capacity,float,1,
GSw_HydroUpgradeCostMult,multiplier on hydro upgrade cost,float,1,
GSw_HydroVarPumpCostRatio,fractional capital cost multiplier for new PSH with variable speed pumps relative to fixed speed,float,1.1,
GSw_Int_CC,"Select intertemporal CC method (0=average undifferentiated, 1=average differentiated , 2=marginal differentiated)",0; 1; 2,0,
GSw_Int_Curt,"Select intertemporal Curt method (0=average undifferentiated, 1=average differentiated , 2=marginal undifferentiated, 3=marginal differentiated)",0; 1; 2; 3,0,
GSw_InterDayLinkage,Turn on (1) or off (0) the ability for interday storage techs (specified in tech-subset-table.csv) to shift energy between representative days (non-interday techs are unaffected),0; 1,0,
GSw_LfillGas,Turn on/off lfill-gas,0; 1,1,
GSw_LoadProfiles,Name of demand profile matching `inputs/profiles_demand/demand_{GSw_LoadProfiles}.h5` OR an absolute filepath to an EER-formatted demand .h5 file,^(historic|EFS_REFERENCE|EFS_MEDIUM|EFS_HIGH|EFS_Clean2035|EFS_Clean2035clip1pct|EFS_Clean2035_LTS|EFS_MEDIUMStretch2040|EFS_MEDIUMStretch2046|EER2023_Baseline_AEO2022|EER2023_IRAlow|EER2023_IRAmoderate|EER2023_100by2050|EER2025_Baseline_AEO2023|EER2025_IRAlow|EER2025_100by2050|\/.+|[a-zA-Z]:[\\\/].+)$,EER2025_IRAlow,
GSw_LoadAllocationMethod,"How to allocate state-level load to model regions ('population' uses each region's share of state population, 'state_lpf' uses county-state load participation factors calculated from the NARIS nodal network dataset)",population; state_lpf,population,
GSw_Loadpoint,Switch to use or disable a loadpoint for the intertemporal solve after the first iteration,0; 1,0,
GSw_LoadSiteCF,Annual capacity factor of optimally sited load (if 0 then optimally sited load is turned off; if between 0 and 1 then load is flexible (obeying stress period weight); if 1 then load is inflexible),float,0,
GSw_LoadSiteRA,Include optimally sited load in PRAS resource adequacy metrics if set to 1 and GSw_LoadSiteCF=1,0; 1,1,
GSw_LoadSiteTrajectory,inputs/load/loadsite_{GSw_LoadSiteTrajectory={hierarchy level}_{identifier}}.csv file indicating load to be optimally sited (only used if GSw_LoadSiteCF>0),^(nercr|transreg|transgrp|cendiv|st|interconnect|country|usda_region)_.*$,country_test,
GSw_MaxCaptureCCSTechs,Switch to enable max capture (_max) CCS techs in addition to _mod. Note that you’ll need to add your own cost and performance for Gas-CC-CCS_max and coal-CCS_max,0; 1,0,
GSw_MaxDailyCF,Turn on/off daily maximum capacity factor constraint,0; 1,1,
GSw_MethaneLeakageScen,Fractional leakage of methane from upstream natural gas production: either float (fixed rate) or scenario name from emission_constraints/methane_leakage_rate.csv,N/A,Alvarez2018_30by2030,
GSw_MGA_CostDelta,MGA: Fraction by which to allow objective function to increase when using Modeling to Generate Alternatives (MGA is turned off if set to 0; a common choice for MGA is 0.01),float,0,
GSw_MGA_Direction,MGA: Directionality of second optimization,(min|max),min,
GSw_MGA_Objective,MGA: Objective for MGA (uses GSw_MGA_SubObjective to specify technology subset if set to capacity),(capacity|generation|transmission|rasharing|co2|employment),capacity,
GSw_MGA_SubObjective,MGA: Technology subset to minimize or maximize the capacity or generation of (only used for GSw_MGA_Objective=(capacity or generation); must be a column of tech-subset-table.csv),(battery|bio|ccs|coal|dac|fossil|gas|gentech|geo|h2_combustion|h2_gen|hydro|nuclear|ofswind|onswind|psh|pv|re|storage|upv|vre|wind),gentech,
GSw_MGA_RV_runs,"MGA: Number of samples drawn for the random vector weights that are applied to variables specified in GSw_MGA_Objective and GSw_MGA_SubObjective. Only active when GSw_MGA_CostDelta != 0; set to an integer N>0 to run N ReEDS simulations with sampling (0 disables sampling).",int,0,
GSw_MGA_RV_region,"MGA: regionality to use with random vector method (active when GSw_MGA_RV_runs>=1)",r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,r,
GSw_MinCF,Turn on/off regional min CF constraint (applied at i/r level),0; 1,1,
GSw_Mingen,Turn on/off min-gen constraints by r/h/szn,0; 1,0,
GSw_MingenFixed,Turn on/off fixed min-gen constraints,0; 1,1,
GSw_MinLoading,Turn on/off the min-loading constraint by i/v/r/h,0; 1,0,
GSw_MinLoadTechs,Specify collection of techs to which to apply min-gen and min-loading constraints (0=none; 1=all; 2=all except geo/csp/lfill; 3=only nuclear/hydro; 4=only steam boiler/hydro),0; 1; 2; 3; 4,4,
GSw_NewValCapShrink,switch to shrink valcap and related conditioning sets post-solve,0; 1,0,
GSw_NG_CRF_penalty,Specify the scenario used for the natural gas CRF penalty,none; ramp_2023_2035; ramp_2045; ramp_2050; reverseramp_2022_2030; reverseramp_high_2022_2030,none,
GSw_NoFossilOffsetCDR,If on (=1) then CO2 removal from DAC/BECCS is only allowed to offset emissions from fossil+CCS and methane leakage,0; 1,0,
GSw_Nuclear,Turn on/off new nuclear (existing nuclear still remains),0; 1,1,
GSw_NuclearDemo,Turn on or off nuclear demonstration plants,0; 1,0,
GSw_NuclearSMR,Turn on [1] / off [0] Nuclear-SMR,0; 1,1,
GSw_NukeCoalFOM,Turn on or off nuclear and coal FOM adders similar to NEMS,0; 1,1,
GSw_NukeFlex,"Switch to enable more flexible nuclear operations (lower mingen, higher ramp rate)",0; 1,0,
GSw_NukeNoRetire,Switch to prevent nuclear from retiring before the year in GSw_NukeNoRetireYear has passed,0; 1,1,
GSw_NukeNoRetireYear,If GSw_NukeNoRetire is enabled nuclear cannot retire through the end of this year,N/A,2032,
GSw_NukeStateBan,Switch to limit nuclear with state bans. [0] off / [1] full ban / [2] cost multiplier,0; 1; 2,1,
GSw_NukeStateBanCostMult,Cost multiplier to represent state nuclear bans if the cost multiplier approach is selected,float,1.5,
GSw_NumCSPclasses,Number of resource classes for CSP,1; 2; 3; 4; 5; 6; 7; 8; 9; 10; 11; 12,12,
GSw_NumGeoclasses,Number of resource classes for Geothermal,1; 2; 3; 4; 5; 6; 7; 8; 9; 10,9,
GSw_OffshoreBackbone,Offshore zones can connect to other offshore zones,0; 1,0,
GSw_OffshoreBackflow,Power can flow from land zones to offshore zones (allowing use of offshore transmission independent of offshore wind generation),0; 1,0,
GSw_OffshoreZones,Add new model zones for offshore resources,0; 1,0,
GSw_OfsWind,Turn on/off offshore wind,0; 1,1,
GSw_OfsWindForceScen,Scenario for state offshore mandates. Select {suffix} from state_policies/offshore_req_{suffix}.csv. Only active if GSw_StateRPS is on,N/A,default,
GSw_OnsWind6to10,Turn on/off onshore wind 6-10,0; 1,1,
GSw_OpRes,Turn on/off operating reserve constraints (0/1) or use simplified version (2),0; 1; 2,2,
GSw_OpResCost,"Case used to select values used for the cost of operating reserves (e.g. default, market)",default; market,default,
GSw_OpResPeriods,Indicate which periods the operating reserve constraint should apply within (representative = clustered; stress/peakload/minre refer to peak load & min-RE periods) (has no effect for GSw_HourlyType=year),representative; all; stress; peakload; minre; peak; vre,peakload,
GSw_OpResReqMult,Multiplier for total reserve requirement (default=1),float,1,
GSw_OpResTradeMult,Multiplier on opres flow in transmission constraint (default=1),float,1,
GSw_OpResTradeLevel,hierarchy level within which to allow opres trading,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,transreg,
GSw_OutageScen,Scenario for forced outage rates,static; murphy2019,murphy2019,
GSw_PRM_CapCredit,Use capacity credit formulation if 1 and stress period formulation if 0,0; 1,0,
GSw_PRM_CapCreditHours,Number of peak net load hour per ccseason considered in capacity credit calculations,int,20,
GSw_PRM_CapCreditMulti,Whether capacity credit is for multi-year (1) or 2012 only (0),0; 1,1,
GSw_PRM_CapCreditSeasons,Season definition to use for capacity credit (2season is hot 4/15-10/14 and cold 10/15-4/14; 4season is meteorological seasons,2season; 4season; 12month,2season,
GSw_PRM_hierarchy_level,hierarchy level within which to calculate peak demand,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,nercr,
GSw_PRM_NetImportLimit,Turn on (1) or off (0) the eq_firm_transfer_limit constraint on max firm net imports (NOTE: This constraint is only applied during stress periods in ReEDS; it is not applied in PRAS),0; 1,1,
GSw_PRM_NetImportLimitScen,/-delimited list of {year}_{max percent import OR 'hist' for historical percent OR 'histmax' for max historical percent across all regions} values to use in eq_firm_transfer_limit,N/A,2031_hist/2050_100,
GSw_PRM_scenario,"column of inputs/reserves/prm_annual.csv from which to draw the PRM (""nerc"" means the annual values from the latest NERC LTRA; ""static"" means the present-year values from the same source); or a float (like 0.12) which gets applied as a fraction to all regions in all years (0.12 means 12%)",(static|nerc|^\d*\.?\d+$),0.12,
GSw_PRM_StressIncrement,How many stress periods to add per iteration,int,2,
GSw_PRM_StressIterateMax,"Max number of times to iterate on a given solve year to achieve adequacy stress levels (e.g., GSw_PRM_StressThresholdNEUE) when using stress periods (0 means don't iterate; 1 means 1 extra ReEDS run; etc)",int,5,
GSw_PRM_StressLoadAggMethod,How to aggregate load for stress periods within the chunks specified by GSw_HourlyChunkLengthStress (only used if GSw_HourlyChunkAggMethod=mean; otherwise GSw_HourlyChunkAggMethod is used),mean; max,max,
GSw_PRM_StressModel,Model used to identify stress periods: pras or a string starting with 'user' which specifies a file at inputs/temporal/stressperiods_{GSw_PRM_StressModel}.csv,N/A,pras,
GSw_PRM_StressOutages,Whether to apply the availability factor (forced + scheduled outages) during stress periods,0; 1,1,
GSw_PRM_StressSeedLoadLevel,Region hierarchy level at which to include peak coincident load days as seeded stress periods (or False to ignore peaks),false; False; FALSE; r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; ccreg,transgrp,
GSw_PRM_StressSeedMinRElevel,Region hierarchy level at which to include minimum wind and solar capacity factor days as seeded stress periods (or False to ignore min-wind/solar CF days),false; False; FALSE; r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; ccreg,interconnect,
GSw_PRM_StressStorageCutoff,How to select shoulder stress periods giving storage time to recharge before/after high-unserved-energy periods. Two-part switch separated by _. The first argument is 'EUE' or 'capacity' or 'absolute'. If 'EUE' the second argument specifies a PRAS storage headspace / EUE threshold [fraction]; if 'cap' it specifies a headspace / storage capacity threshold [fraction]; if 'abs' it specifies absolute number of periods before/after [integer]. Turned off if set to 'off'.,N/A,EUE_0.1,
GSw_PRM_StressThresholdMetrics,/-delimited list of metrics for identifying stress periods; supported metrics (case-insensitive) are: LOLD | LOLE | LOLH | NEUE | Depth | Duration,N/A,NEUE,
GSw_PRM_StressThresholdDepth,Outage depth threshold [MW_EUE/MW_peak_load] (fraction); formulated as HierarchyLevel_Depth where HierarchyLevel is a column in hierarchy.csv; Depth is the max outage magnitude in [MW EUE] / [MW peak demand],N/A,transgrp_0.1,
GSw_PRM_StressThresholdDuration,Outage duration threshold [hours]; formulated as HierarchyLevel_Duration where HierarchyLevel is a column in hierarchy.csv; Duration is the max outage duration in hours,N/A,transgrp_12,
GSw_PRM_StressThresholdLOLD,LOLD threshold [event-days/year]; formulated as HierarchyLevel_LOLD where HierarchyLevel is a column in hierarchy.csv; LOLD is loss-of-load event-days per year,N/A,transgrp_0.1,
GSw_PRM_StressThresholdLOLE,LOLE threshold [events/year]; formulated as HierarchyLevel_LOLE where HierarchyLevel is a column in hierarchy.csv; events is loss-of-load events per year,N/A,transgrp_0.1,
GSw_PRM_StressThresholdLOLH,LOLH threshold [event-hours/year]; formulated as HierarchyLevel_LOLH where HierarchyLevel is a column in hierarchy.csv; LOLH is loss-of-load event-hours per year,N/A,transgrp_2.4,
GSw_PRM_StressThresholdNEUE,NEUE threshold [ppm]; formulated as HierarchyLevel_NEUE where HierarchyLevel is a column in hierarchy.csv; NEUEppm is normalized expected unserved energy in parts per million,N/A,transgrp_1,
GSw_PRM_CVARalpha,[fraction] Alpha value (percentile (expressed as a fraction) above which to average the tail; 0.95 means the 95th percentile) used for CVAR/NCVAR calculations,float,0.95,
GSw_PRM_UpdateFraction,Fraction to add to the PRM if a region fails RA threshold (only used if GSw_PRM_UpdateMethod = 1),float,0.02,
GSw_PRM_UpdateMethod,Option to update PRM: (0) no update; (1) static update set by GSw_PRM_UpdateFraction; (2) dynamic update informed by PRAS; (3) dynamic update but only after all new stress periods have been added,0; 1; 2; 3,0,
GSw_PRMTRADE_level,hierarchy level within which to allow PRM trading,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,country,
GSw_PSHfillyears,switch to define the number of years it is assumed to take to fill PSH reservoirs [only relevant with water constraints active],N/A,3,
GSw_PSHwatertypes,switch to define what types of water is available for filling PSH reservoirs (0=fresh surface/ground water; 1=fresh surface water; 2=all types except saline surface water) [only relevant with water constraints active],0; 1; 2,0,
GSw_PSHwatercon,binary switch to turn water constraints for PSH on and off,0; 1,0,
GSw_PVB,Turn on/off hybrid PV+Battery,0; 1,0,
GSw_PVB_BIR,'_'-delimited battery/inverter capacity ratio for the three PVB types expressed as a percentage [e.g. 50_75_100],N/A,25,
GSw_PVB_Dur,Hybrid PV+Battery duration; the battery portion will use the same inputs as battery_li,N/A,4,
GSw_PVB_ILR,'_'-delimited inverter loading ratio for the three PVB types expressed as a percentage [e.g. 130_180_240],N/A,134,
GSw_PVB_BatteryITC,Switch to apply ITC to battery in PV+B.,0; 1,1,
GSw_PVB_Charge_Constraint,Fraction of battery charging in PV+B that is constrained to be from coupled PV; a value of zero turns off the constraint.,N/A,0,
GSw_PVB_Types,'_'-delimited PV+battery types to include (i.e. 1 or 1_2 or 1_2_3),N/A,1,
GSw_QueueConstraintYears,How many years (starting from and including this_year) to apply the interconnection queue capacity constraint for (0 turns off the constraint),^[0-5]$,3
GSw_ReducedResource,Turn on/off switch to reduce the RE resource available,0; 1,0,
GSw_Refurb,Turn on/off refurbishments,0; 1,1,
GSw_RemoveSmallNumbers,Turn on/off rounding of variables known to cause very small values on the RHS of certain constraints (improve numerical stability),0; 1,1,
GSw_RetailAdder,2004$/MWh adder to the cost of electricity consumed by hydrogen production and DAC facilities,float,0,
GSw_Retire,Endogenous retirement: 0 = no endogenous retirement; 1 = any existing plants can retire; 2 = only existing coal/gas can retire; 3 = new/existing nuclear/coal/gas can retire after minimum age; 4 = new/existing plants of any tech can retire; 5 = same as 3 but nuclear can only retire after 2030,0; 1; 2; 3; 4; 5,5,
GSw_RetirePenalty,Apply a penalty for retiring a power plant early to represent retirement friction,0; 1,1,
GSw_RetireYear,Year to begin endogenous retirements,N/A,2027,
GSw_RetireYears_Coal,"Adjust lifetime coal retirements [0 = coal retirements straight from EIA unit database, negative number = number of years decreased in the lifteime of currrently operating coal plants, positive number = number of years increased in the lifetime of all currently operating coal units]. This switch is ignored if GSw_RetireYears_Thermal (below) is non-zero since GSw_RetireYears_Thermal adjusts retirement years of all thermal units including coal units.",int,0,
GSw_RetireYears_Thermal,"Adjust lifetime thermal retirements [0 = thermal retirements straight from EIA unit database, negative number = number of years decreased in the lifteime of currrently operating thermal plants, positive number = number of years increased in the lifetime of all currently operating thermal units]",int,0,
GSw_RGGI,Turn on/off RGGI,0; 1,1,
GSw_SitingGeo,Specify the Geothermal siting scenario,reference,reference,
GSw_SitingUPV,Specify the UPV siting scenario,open; reference; limited,reference,
GSw_SitingWindOfs,Specify the offshore wind siting scenario,open; reference; limited,reference,
GSw_SitingWindOns,Specify the onshore wind siting scenario,open; reference; limited,reference,
GSw_SkipRAyear,Last year in which to skip running the resource adequacy (RA) calculations,N/A,2024,
GSw_SpurCostMult,Multiplier for spur-line costs,float,1,
GSw_SpurScen,Spur-line scenario: 0 to include in resource supply curve; 1 to model endoegenously,0; 1,0,
GSw_SpurShare,Indicate whether wind-ons and upv are allowed to share spur line capacity,0; 1,0,
GSw_StartMarkets,Indicate year in which load-balance and operating-reserve constraints start to be enforced,N/A,2027,
GSw_StartCost,Technologies with startup costs (0=none; 1=nuclear; 2=nuclear/coal/ccs; 3=coal/ccs; 4=coal/cc/ccs; 5=all fuel-based except nuclear; 6=all fuel-based) (default is to leave out nuclear since it's always committed with GSw_MingenFixed=1),0; 1; 2; 3; 4; 5; 6,3,
GSw_StateCap,Turn on/off state cap and trade constraints,0; 1,1,
GSw_StateRPS,Turn on/off state RPS requirements,0; 1,1,
GSw_StateRPS_Carveouts,Turn wind and solar carveouts off/on,0;1,0,
GSw_StateCO2ImportLevel,Hierarchy level within which to calculate CO2 emissions rate [metric ton/MWh] for state CO2 caps,r; nercr; transreg; cendiv; st; interconnect; country; usda_region,interconnect,
GSw_Storage,0=ban storage; 1=use all standalone storage techs,0; 1,1,
GSw_StorageBinPenalty,Turn on/off the storage bin penalty for the PRM method (when on results in better firm capacity outputs),0; 1,1,
GSw_TechCostAdjust,"Fractional adjustments to overnight capital costs by technology group and year (inputs/plant_characteristics/tech_cost_adjustments_{GSw_TechCostAdjust}.csv). Groups are column names in inputs/tech-subset-table.csv; 'none' applies no adjustment",none; ATB_2025,none,
GSw_TCPhaseout,Switch for whether tax credit Phaseout is enabled (0=no; 1=yes),0; 1,1,
GSw_TCPhaseout_forceyear,(0=off by default) Indicate a year in which to force the start of the tax credit phaseout,N/A,2032,
GSw_TCPhaseout_ref_year,The reference year used to determine whether the trigger for the tax credit phaseout threshold has been hit (with 100by),N/A,2022,
GSw_TCPhaseout_schedule,The schedule by which the tax credits phase out. This assumes that the phaseout schedule starts on the year after the threshold is met. The phaseout may still have a period of full credit after the trigger has been met depending on the policy definition.,ira2022,ira2022,
GSw_TCPhaseout_start,Earliest allowed Applicable Year for the tax credit phaseout. The tax credit phaseout schedule starts on the year following this year; or later if the emission threshold is not met by this year,N/A,2032,
GSw_TCPhaseout_trigger_f,The fraction of emissions from the ref year used to determine whether the trigger for the tax credit phaseout has been hit,float,0.25,
GSw_TransCapMaxEachType,[GW] maximum transmission capacity allowed across each individual BA-BA interface for each trtype (constraint is off if set to 0; must be 0 or >= existing capacity (26.13 for AC)),N/A,0,
GSw_TransCapMaxAllTypes,[GW] maximum transmission capacity allowed across each individual BA-BA interface for all trtypes together (constraint is off if set to 0; must be 0 or >= existing capacity (26.13 for AC)),N/A,0,
GSw_TransCapMaxTypes,Transmission types to limit according to GSw_TransCapMaxEachType and GSw_TransCapMaxAllTypes [0 = none; 1 = all; 2 = VSC; 3 = all DC],0; 1; 2; 3,1,
GSw_TransConductor,Which conductor to assume for new AC transmission ('acss' is a mix of ACSS and ACSR as specified by the MISO Transmission Cost Estimation Guide; 'acsr' is just ACSR),^(acss|acsr)$,acsr,
GSw_TransIntraCost,[USD2004/kW] intra-zone network reinforcement cost for all technologies (100 USD2022/kW using gas cost from slide 14 of https://emp.lbl.gov/publications/generator-interconnection-costs),N/A,65,
GSw_TransInvMaxLongTerm,[TW-mile/year] maximum transmission capacity investment per year IN/AFTER firstyear_trans_longterm (constraint is OFF if set to 0 meaning unlimited trans investment; annual max since 2009 is ~3.64),N/A,0,
GSw_TransInvMaxNearTerm,[TW-mile/year] maximum transmission capacity investment per year BEFORE firstyear_trans_longterm (constraint is OFF if set to 0 meaning unlimited trans investment; annual mean since 2009 is ~1.4),float,1.4,
GSw_TransInvNearTerm,Indicate whether to allow transmission investment before firstyear_trans_longterm,0; 1,0,
GSw_TransInvMaxTypes,Types of transmission to include in annual investment limit: 0=none; 1=interzonal (r); 2=interzonal + reinforcement; 3=interzonal + reinforcement + spur,0; 1; 2; 3,1,
GSw_TransInvPRMderate,[fraction] amount by which to derate the capacity of new transmission investments for PRM trading (0 = no derate),float,0.15,
GSw_TransCostMult,Multiplier for bulk BA-BA transmission costs,float,1,
GSw_TransHurdleLevel1,Apply hurdle rates from inputs/transmission/cost_hurdle_intra.csv between regions at the specified hierarchy level,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; hurdlereg,transgrp,
GSw_TransHurdleLevel2,Apply hurdle rates from inputs/transmission/cost_hurdle_intra.csv between regions at the specified hierarchy level,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region; hurdlereg,hurdlereg,
GSw_TransHurdleRate,Turn on (1) or off (0) hurdle rates between hierarchy regions as defined by GSw_TransHurdleLevel1/GSw_TransHurdleLevel2 and inputs/transmission/cost_hurdle_intra.csv,0; 1,0,
GSw_TransNetworkSource,Network source for the initial transmission network used in the model,NARIS2024,NARIS2024,
GSw_TransRestrict,hierarchy level within which to allow new transmission lines,r; nercr; transreg; transgrp; cendiv; st; interconnect; country; usda_region,country,
GSw_TransScen,Additional candidate interfaces for transmission expansion between zones,^(none|NTP_(MT|P2P))$,none,
GSw_TransSquigglinessMin,Minimum squiggliness (straight-line length multiplier) to apply for interzonal transmission; the default value is from the MISO Transmission Cost Estimation Guide (https://www.misoenergy.org/planning/transmission-planning/mtep),float,1.3,
GSw_TransUpgradeMethod,Method for calculating interzonal AC transmission expansion costs,^(greenfield|500kv)$,greenfield,
GSw_TransGroupContraint,Indicate whether to apply flow constraint on groups of transmission interfaces,0; 1,1,
GSw_TransGroupDerate,[fraction] amount by which to derate the capacity of grouped transmission flows for new transmission additions (0 = no derate),float,0.15,
GSw_Upgrades,Switch to turn upgrades on or off - not to be used with water constraints - value of 2 indicates persistent upgrades,0; 1; 2,1,
GSw_UpgradeLifespan,Lifespan for retirements when sw_upgrades is set to 1,N/A,50,
GSw_UpgradeYear,First year when upgrades are allowed,N/A,2028,
GSw_UpgradeChar_Year,Year from which to grab the characteristics for upgraded init-X plant characteristics,N/A,2028,
GSw_UpgradeDerate,Switch to turn upgrade degrades off/on,0; 1,1,
GSw_UpgradeHeatRateAdj,Use HeatRate for upgrades from NEMS,0; 1,1,
GSw_UpgradeATBCosts,Use ATB upgrade costs,0; 1,0,
GSw_UpgradeVOM_Nems,Use VOM for upgrades from NEMS ,0; 1,1,
GSw_UpgradeFOM_Nems,Use FOM for upgrades from NEMS,0; 1,1,
GSw_UpgradeCost_Mult,"specify scenario for controlling upgrades over time - 0=mid 1=adv 2=con, 3=1, 4=1+(1-mid), 5=1.2",0; 1; 2; 3; 4; 5,0,
GSw_Upstream,Include both upstream and process emissions in CO2 and CO2e calculation if 1 and only process emission if 0,0; 1,0,
GSw_ValStr,Turn on/off value streams,0; 1,0,
GSw_VSC_ConverterMax,maximum AC/DC converter capacity allowed in each BA [MW] (constraint is off if set to 0),N/A,0,
GSw_WaterCapacity,Turn on/off the water capacity constraints,0; 1,0,
GSw_WaterMain,Turn on/off the representation of water use and source types,0; 1,0,
GSw_WaterUse,Turn on/off the water capacity and water use constraints,0; 1,0,
debug,Write and keep intermediate files and equation elements to help with debugging. The value of the switch is passed to `option limrow` and `option limcol` and indicates the number of equation and variable entries to print,int,0,
cleanup_level,How aggressively to clean up the case folder (see postprocessing/cleanup_files.py for explanation),int,0,
diagnose,Write A and B matrix of the model [0 = no diagnose ; 1 = diagnose ],0; 1,0,
diagnose_year,Year in which to start report diagnose,N/A,2022,
dump_alldata,switch to automatically dump data from final solve year into .gdx file,0; 1,0,
file_replacements,"List of files to replace from run folder, e.g: inputs_case/national_gen_frac.csv << //nrelnas01/ReEDS/some_project/national_gen_frac.csv || c_model.gms << //nrelnas01/ReEDS/some_project/c_model.gms",N/A,none,
input_processing_only,Only run input_processing scripts; stop before creating and solving model (1) or stop right after Monte Carlo sampling (2),0; 1; 2,0,
keep_resource_adequacy_files,Indicate whether to keep (1) or delete (0) resource adequacy csv and h5 files after RA calculations finish,0; 1,0,
keep_g00_files,Keep (1) or delete (0) .g00 files for completed solve years,0; 1,0,
keep_run_terminal,"0=close run terminal, 1=keep run terminal open",0; 1,0,
land_use_analysis,switch to turn on/off land-use analysis. Requires the `reeds_to_rev` switch also be activated,0; 1,0,
pcm,Rerun final solve year in dispatch mode at 1-hour resolution after the CEM run finishes (submits a new bigmem job if on the HPC),0; 1,0,
plot_ba_level,0=do not plot or output BA-level year-by-month plots; 1=plot and output BA-level year-by-month plots.,0; 1,0,
pras,Indicate whether to run PRAS for 2007-2013 between each pair of solve years (0=never; 1=just the final solve year; 2=always),0; 1; 2,2,
pras_agg_ogs_lfillgas,Aggregate existing o-g-s and landfill gas units to the capacity assumed for new units (from unitsize.csv),0; 1,0,
pras_existing_unit_size,Use the average size of existing units by tech/region when disaggregating new capacity (otherwise use capacities from unitsize.csv for all new units),0; 1,1,
pras_hydro_energylim,Whether to model hydro as energy-limited in PRAS (1) or like a thermal generator (0),0; 1,1,
pras_include_h2dac,Indicate whether to include (1) demand associated with H2 production & DAC in PRAS,0; 1,0,
pras_max_unitsize_prm,Cap the upper bound of disaggregated unit size by zone at the zonal PRM in MW,0; 1,1,
pras_samples,Indicate how many Monte Carlo samples to use in PRAS (if 0 then the .pras file is generated but PRAS is not run),int,100,
pras_scheduled_outage,Include scheduled outages in PRAS (if 0 then a default outage rate of 0 is applied),0; 1,0,
pras_seed,Seed to use for PRAS samples; can be any positive integer. If 0 the seed is set randomly,int,1,
pras_singlethread,Force single-thread operation for PRAS (much slower but sometimes helps avoid Julia hangs and errors),^[0-1]$,0,
pras_trans_contingency,Indicate whether to use energy (0) or PRM (1) transmission capacities in PRAS,0; 1,0,
pras_unitsize_source,Data source for characteristic unit sizes in ReESD2PRAS,atb; r2x,atb,
pras_vre_combine,Combine VRE into a single VRE tech in ReEDS2PRAS,0; 1,0,
reeds_to_rev,switch to turn on/off ReV outputs,0; 1,1,
resource_adequacy_years,_-delimited years to include in resource adequacy calculations,N/A,2007_2008_2009_2010_2011_2012_2013_2016_2017_2018_2019_2020_2021_2022_2023,
MCS_runs,Number of Monte Carlo simulation runs. Set to 0 to disable MCS. Set to an integer N > 0 to run N ReEDS simulations with sampling.,int,0,
MCS_dist,Name of the `.yaml` file defining the MCS distributions. Use 'default' or a string beginning with 'user' to reference `inputs/userinput/mcs_distributions_{MCS_dist}.yaml`,N/A,default,
MCS_dist_groups,Define the distribution groups to use in a Monte Carlo Simulation. Each entry should refer to a key from `inputs/userinput/mcs_distributions_{MCS_dist}.yaml` with multiple entries separated by a dot (e.g. Example1.Example2.Example3),N/A,tech,
MCS_lhs,Option to use random sampling (0) or latin hypercube sampling (1) for Monte Carlo simulation (also applies to MGA random vector method when not using discrete sample values),0; 1,0,