Notifications
You must be signed in to change notification settings - Fork 13
Expand file tree
/
Copy pathnodeimu.cpp
More file actions
134 lines (107 loc) · 4.14 KB
/
nodeimu.cpp
File metadata and controls
134 lines (107 loc) · 4.14 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
#include "nodeimu.h"
#include <nan.h>
using namespace v8;
NodeIMU::NodeIMU() {
settings = new RTIMUSettings("RTIMULib");
imu = RTIMU::createIMU(settings);
pressure = RTPressure::createPressure(settings);
humidity = RTHumidity::createHumidity(settings);
if ((imu == NULL) || (imu->IMUType() == RTIMU_TYPE_NULL)) {
printf("No IMU found\n");
exit(1);
}
imu->IMUInit();
if (pressure != NULL) { pressure->pressureInit(); }
if (humidity != NULL) { humidity->humidityInit(); }
imu->setSlerpPower((float)0.02);
imu->setGyroEnable(true);
imu->setAccelEnable(true);
imu->setCompassEnable(true);
}
NodeIMU::~NodeIMU() {
delete imu;
delete settings;
delete pressure;
delete humidity;
}
NAN_METHOD(NodeIMU::New) {
NodeIMU* obj = new NodeIMU();
obj->Wrap(info.This());
info.GetReturnValue().Set(info.This());
}
void AddRTVector3ToResult(v8::Local<v8::Object>& result, RTVector3 data, const char* name) {
Nan::HandleScope();
v8::Local<v8::Object> field = Nan::New<v8::Object>();
Nan::Set(field, Nan::New("x").ToLocalChecked(), Nan::New(data.x()));
Nan::Set(field, Nan::New("y").ToLocalChecked(), Nan::New(data.y()));
Nan::Set(field, Nan::New("z").ToLocalChecked(), Nan::New(data.z()));
Nan::Set(result, Nan::New(name).ToLocalChecked(), field);
}
void PutMeasurement(const RTIMU_DATA& imuData, const bool pressure, const bool humidity, v8::Local<v8::Object>& result) {
Nan::HandleScope();
Nan::Set(result, Nan::New("timestamp").ToLocalChecked(), Nan::New<v8::Date>(0.001 * (double)imuData.timestamp).ToLocalChecked());
AddRTVector3ToResult(result, imuData.accel, "accel");
AddRTVector3ToResult(result, imuData.gyro, "gyro");
AddRTVector3ToResult(result, imuData.compass, "compass");
AddRTVector3ToResult(result, imuData.fusionPose, "fusionPose");
Nan::Set(result, Nan::New("tiltHeading").ToLocalChecked(), Nan::New(RTMath::poseFromAccelMag(imuData.accel, imuData.compass).z()));
if (pressure) {
Nan::Set(result, Nan::New("pressure").ToLocalChecked(), Nan::New(imuData.pressure));
Nan::Set(result, Nan::New("temperature").ToLocalChecked(), Nan::New(imuData.temperature));
}
if (humidity) {
Nan::Set(result, Nan::New("humidity").ToLocalChecked(), Nan::New(imuData.humidity));
}
}
class SensorWorker : public Nan::AsyncWorker {
public:
SensorWorker(Nan::Callback *callback, RTIMU* imu, RTPressure *pressure, RTHumidity *humidity)
: AsyncWorker(callback), d_imu(imu), d_pressure(pressure), d_humidity(humidity) {}
~SensorWorker() {}
// Executed inside the worker-thread.
// It is not safe to access V8, or V8 data structures
// here, so everything we need for input and output
// should go on `this`.
void Execute() {
if (d_imu->IMURead()) {
d_imuData = d_imu->getIMUData();
if (d_pressure != NULL) { d_pressure->pressureRead(d_imuData); }
if (d_humidity != NULL) { d_humidity->humidityRead(d_imuData); }
}
}
// Executed when the async work is complete
// this function will be run inside the main event loop
// so it is safe to use V8 again
void HandleOKCallback() {
Nan::HandleScope scope;
v8::Local<v8::Object> result = Nan::New<v8::Object>();
PutMeasurement(d_imuData, d_pressure != NULL,d_humidity != NULL, result);
v8::Local<Value> argv[] = {
Nan::Null(), result
};
callback->Call(2, argv);
}
private:
RTIMU* d_imu;
RTPressure *d_pressure;
RTHumidity *d_humidity;
RTIMU_DATA d_imuData;
};
NAN_METHOD(NodeIMU::GetValue) {
NodeIMU* obj = Nan::ObjectWrap::Unwrap<NodeIMU>(info.This());
Nan::Callback *callback = new Nan::Callback(info[0].As<Function>());
Nan::AsyncQueueWorker(new SensorWorker(callback, obj->imu, obj->pressure, obj->humidity));
}
NAN_METHOD(NodeIMU::GetValueSync) {
NodeIMU* obj = Nan::ObjectWrap::Unwrap<NodeIMU>(info.This());
if (obj->imu->IMURead()) {
RTIMU_DATA imuData = obj->imu->getIMUData();
bool pressure = (obj->pressure != NULL);
bool humidity = (obj->humidity != NULL);
if (pressure) { obj->pressure->pressureRead(imuData); }
if (humidity) { obj->humidity->humidityRead(imuData); }
v8::Local<v8::Object> result = Nan::New<v8::Object>();
PutMeasurement(imuData, pressure, humidity, result);
info.GetReturnValue().Set(result);
}
}