Skip to content

About

No description, website, or topics provided.

Resources

Contributing

Stars

1 star

Watchers

2 watching

Forks

Repository files navigation

Analytic simulation of PETSIRD v0.13.3 data using parallelproj

This tool allows to "quickly" simulate and reconstruct PETSIRD TOF listmode data using a simplified physics model (true unscattered coincidences including attenuation, and random coincidences) and non-trivial detection efficiencies.

One of its aims is to be able to generate data that can be used to test implementations of software supporting the PETSIRD standard for listmode data.

Requirements:

  • PETSIRD v0.13.x (>= 0.13.3)
  • parallelproj v2.x (requires python >= 3.12)
  • matplotlib (plots and the interactive 3-axis viewer in python/viewer.py)

Create your conda / mamba environment

conda env create -f environment.yml
conda activate petsird-analytic-simulator
cd python

Simulate PETSIRD LM data

python 01_analytic_petsird_lm_simulator.py

The simulation script creates a binary PETSIRD LM file and reference files for testing readers / reconstructions of PETSIRD data, which are all stored in the output directory (by default data/sim_{phantom}_{num_true_counts}_{seed}_{backend}, where backend is petsird or petsird_fast, see --petsird_backend)

tree --charset=ascii data/sim_uniform_cylinder_4000000_0_petsird_fast

data/sim_uniform_cylinder_4000000_0_petsird_fast
|-- attenuation_image.nii
|-- ground_truth_image.nii
|-- petsird_geometry_and_events.png
|-- petsird_summary.txt
|-- prompts_randoms_expectation.npy
|-- randoms_expectation.json
|-- reference_sensitivity_image.nii
|-- sim_parameters.json
`-- simulated_petsird_lm_file.bin
file content
simulated_petsird_lm_file.bin the PETSIRD listmode file
sim_parameters.json the parameters of the simulation
ground_truth_image.nii ground truth activity image, i.e. before the image-based resolution model (--fwhm_mm) which is part of the forward model of the simulation
attenuation_image.nii attenuation image (1 / mm) of the water body of the phantom, to be used for attenuation correction
reference_sensitivity_image.nii sensitivity image of the forward model of the simulation (efficiencies, attenuation, image-based resolution model)
prompts_randoms_expectation.npy true (noise-free) expected randoms in the data bin (pair of detection bins and TOF bin) of every prompt, in the order of the prompts in the PETSIRD file: the additive contamination of a TOF LM reconstruction (multiply by the number of TOF bins for non-TOF)
randoms_expectation.json true (noise-free) expectation of the randoms: random fraction, expected trues and randoms, (scaled) singles of all detection bins (to test randoms corrections and estimations)
petsird_summary.txt (only with --petsird_summary) human-readable summary of the PETSIRD file (output of petsird.helpers.analysis, which reads all events with the yardl-generated Python code and is slow for large files)
petsird_geometry_and_events.png visualization of the PETSIRD geometry and the first events (see below)
lm_backprojection_tof.nii (only with --save_lm_backprojection) TOF LM backprojection of the events before writing them to PETSIRD
reference_histogram_mlem_<n>_epochs.nii (only with --num_epochs_mlem n) MLEM reconstruction of the histogrammed data with the exact forward model of the simulation

All images are NIfTI files (see Image files), centered at (0,0,0) with the voxel size --voxel_size.

Randoms: the prompts contain true coincidences and random coincidences with an expected random fraction R / (T + R) given by --random_fraction (default 0.5, where T are the (attenuated) trues and R the randoms). The expected randoms of a LOR (pair of detection bins a, b of modules in coincidence, summed over all TOF bins) are the product of the (scaled) singles s_a * s_b, and the randoms are uniformly distributed over the TOF bins. The singles of a detecting element are its efficiency (0 for "dead" elements) times 50% uniform + 50% flux from the activity in the FOV (the efficiency corrected fan sum of its expected trues, normalized to mean 1), such that they vary with the activity distribution and the efficiencies (see singles_model in python/simulation.py). An independent Poisson realization of the randoms is stored as delayed coincidences. The singles counts of all detecting elements in every time block are stored as singles histograms (singles_histogram_level ALL, ideal singles: same energy window as the coincidences, no dead time). They are Poisson realizations of constant singles rates S such that the randoms are 2 tau T S_a S_b (acquisition time T), where the coincidence window 2 tau is the range covered by the TOF bins ((t1 - t2) range = 2 x TOF bin range / c, ≈ 1.02 ns for the defaults). The true singles, singles rates and coincidence window are saved in randoms_expectation.json. With --random_fraction 0, no randoms, no delayeds and no singles are simulated.

petsird_geometry_and_events.png visualizes (transaxial, sagittal and 3D views) the PETSIRD scanner geometry as written to the file (detecting element boxes with front faces and box axes, average detection points, module and detecting element indices) and the first events (detection bins and the emission position decoded from the TOF bin following the PETSIRD definition) on top of the ground truth activity (see python/geometry_plots.py).

The following phantoms are available (--phantom):

  • uniform_cylinder: uniform cylinder centered in the field of view
  • offcenter_cylinder: cylinder that is off-center (transaxially and axially) with 3 hot spheres of different size (radius 8, 6, 4 mm), contrast (3:1, 2:1, 3:1) and position. Since the phantom has no symmetry, axis flips, swaps and mirroring (e.g. in readers of the PETSIRD data) are visible in the reconstructions.
  • points: point sources (in a centered water cylinder)
  • uniform_cylinder_text: uniform_cylinder with hidden low-contrast letters (--phantom_text, default PET, --phantom_text_contrast, default 0.15), see Reconstruction challenge

--phantom_image activity.nii (and optionally --phantom_attenuation_image mu.nii, default: water where the activity is > 0) simulates any activity image (NIfTI in the scanner coordinate system, resampled onto the simulation grid if needed) instead.

All phantoms are embedded in a water body (linear attenuation coefficient 0.0096 / mm) whose attenuation is included in the simulated data. The attenuation image (in 1 / mm) is saved as attenuation_image.nii and can be used for attenuation correction in the reconstruction (see below).

The simulation can be customized in many ways (number of counts to simulate, uniform or non-uniform efficiencies ...) via command line options.

These options can be listed via

python 01_analytic_petsird_lm_simulator.py -h

Output Configuration:
  --fname FNAME         name of the output LM file (default: simulated_petsird_lm_file.bin)
  --output_dir OUTPUT_DIR
                        directory to save output files (default: None)
  --skip_writing        skip writing the LM data to a file (default: False)
  --petsird_summary     write a human-readable summary of the PETSIRD file (petsird_summary.txt,
                        output of petsird.helpers.analysis, which reads all events with the
                        yardl-generated Python code and is slow for large files) (default: False)

Image and Phantom Configuration:
  --phantom {uniform_cylinder,offcenter_cylinder,points,uniform_cylinder_text}
                        phantom to simulate (ignored if --phantom_image is given) (default:
                        uniform_cylinder)
  --phantom_text PHANTOM_TEXT
                        letters of the phantom uniform_cylinder_text (one per axial section)
                        (default: PET)
  --phantom_text_contrast PHANTOM_TEXT_CONTRAST
                        contrast of the letters of the phantom uniform_cylinder_text (default:
                        0.15)
  --phantom_image PHANTOM_IMAGE
                        activity image (NIfTI, in the scanner coordinate system) to simulate
                        instead of --phantom, resampled onto the simulation grid if needed
                        (default: None)
  --phantom_attenuation_image PHANTOM_ATTENUATION_IMAGE
                        attenuation image (NIfTI, 1/mm) of --phantom_image (default: water where
                        the activity is > 0) (default: None)
  --img_shape IMG_SHAPE
                        shape of the image to simulate (default: (55, 55, 21))
  --voxel_size VOXEL_SIZE
                        voxel size in mm used in the simulation (default: (2.0, 2.0, 2.0))

Physics / simulation parameters:
  --fwhm_mm FWHM_MM     FWHM of the image space resolution model in mm (default: 2.5)
  --tof_fwhm_mm TOF_FWHM_MM
                        FWHM of the TOF resolution model in mm (default: 10.0)
  --num_true_counts NUM_TRUE_COUNTS
                        (expected) number of true coincidences to simulate (default: 4000000)
  --random_fraction RANDOM_FRACTION
                        (expected) random fraction R / (T + R) of the prompts, where R / T are the
                        total randoms / (attenuated) trues; the randoms are also stored as
                        independent realization in the delayed coincidences (0 means no randoms
                        and no delayeds) (default: 0.5)

Scanner Geometry:
  --modules_per_panel {1,2}
                        2: 6 flat panels of 2 modules around the scanner axis (only symmetric
                        under a rotation by one panel, i.e. 60 deg), 1: 12 modules equally spaced
                        around the axis (default: 2)
  --panel_gap PANEL_GAP
                        gap between the modules of a panel (mm) (default: 4.0)
  --num_axial_modules NUM_AXIAL_MODULES
                        number of axial module positions (the transaxial arrangement of 12
                        modules is repeated at each axial position) (default: 3)
  --axial_gap AXIAL_GAP
                        gap between neighboring axial module positions (mm) (default: 2.0)
  --block_shape BLOCK_SHAPE
                        number of detecting elements (4.5 x 10 x 4.5 mm) per module (tangential,
                        radial, axial) (default: (10, 2, 3))

Detection Efficiency Parameters:
  --efficiency_model {structured,random}
                        structured: exaggerated, structured detecting element and module pair
                        efficiencies (sectors, rings, axial profiles, a dead patch; clear
                        artifacts if they are ignored or misinterpreted), random: random
                        efficiencies (previous model) (default: structured)
  --uniform_crystal_eff
                        use uniform crystal efficiencies, otherwise use a random distribution
                        (default: False)
  --uniform_sg_eff      use uniform symmetry group (module pair) efficiencies, otherwise pseudo
                        random pattern is used (default: False)

Time Block Configuration:
  --num_time_blocks NUM_TIME_BLOCKS
                        number of time blocks to split the data into (default: 100)
  --event_block_duration EVENT_BLOCK_DURATION
                        duration of each time block in ms (default: 100)

Reconstruction and Analysis:
  --num_epochs_mlem NUM_EPOCHS_MLEM
                        number of epochs for MLEM reconstruction of histogrammed data, 0 means no
                        MLEM reconstruction (default: 0)
  --save_lm_backprojection
                        save the TOF LM backprojection of the simulated events (before writing them
                        to PETSIRD, used to check the written events) (default: False)

Visualization and Debugging:
  --skip_plots          skip plotting the PETSIRD scanner geometry and events (default: False)

General Options:
  --seed SEED           random seed for reproducibility (default: 0)
  --petsird_backend {auto,petsird,petsird_fast}
                        write the time blocks with the yardl-generated Python code (petsird) or
                        the optional compiled package petsird_fast (C++, much faster, byte-
                        identical files); auto: petsird_fast if installed (default: auto)

Note: The "reference" MLEM using histogrammed data is only run if a value > 0 is given via --num_epochs_mlem. Otherwise it is skipped to save time.

Simulated scanner

36 modules of 10 x 2 x 3 (tangential x radial x axial) LYSO crystals (4.5 x 10 x 4.5 mm), 2160 crystals in total:

  • transaxially, 12 modules form 6 flat panels of 2 modules each (--modules_per_panel 2, panel center 100 mm from the scanner axis, 4 mm gap between the modules of a panel)
  • axially, this arrangement is repeated at 3 axial module positions (--num_axial_modules 3, 2 mm gap, axial extent 44.5 mm, centered at z = 0)

Module index = 12 * axial module index + transaxial module index. The transaxial module index increases counterclockwise (also within a panel), so transaxial modules 2k and 2k + 1 form panel k, rotated by 60 * k degrees; the axial module index increases along +z. Module pairs with a transaxial circular index distance of at least 3 are in coincidence, for all axial module offsets (0, 1, 2).

--modules_per_panel 1 --num_axial_modules 1 --block_shape 10,2,9 gives the original geometry (12 modules of 10 x 2 x 9 crystals equally spaced around the axis, facing the scanner center).

petsird_geometry_and_events.png (written by the reconstruction) shows the geometry as encoded in the PETSIRD file (transaxial, sagittal and 3D views).

The geometry is deliberately not very symmetric:

  • it is only symmetric under a rotation by one panel (60 deg), not by one module (30 deg). Two module pairs with the same transaxial module offset are therefore in general not equivalent (e.g. transaxial modules 3 / 0 are 2 panels apart, 4 / 1 are 1 panel apart, both have offset 3).
  • module pairs (not the scanner) are in addition symmetric under an axial shift by one axial module position: the module pairs (12 + i, 12 + j) and (i, j) are equivalent.
  • the axial mirror (z -> -z) is not used: it reverses the order of the detecting elements within a module, which is neither the same nor the transposed module pair efficiency matrix.

Readers that assume that the module pair efficiencies only depend on the module index difference, or that the SGID LUT is one triangle, give wrong results.

Notes on the PETSIRD encoding

  • Coincidences are stored ordered, i.e. detection_bins[0] >= detection_bins[1]. The TOF index tof_idx refers to (t1 - t2) * c / 2 where t1 / t2 are the arrival times at the first / second detection bin.

  • All tables over pairs of module (types) (TOF bin edges and resolution, prompt events, module pair SGID LUT, module pair efficiencies) are lower-triangular.

  • The detecting elements are boxes oriented along their local x-axis (pointing away from the scanner center, along the normal of their panel) with the average detection point at the crystal center. Their material (LYSO, material_id 1) is defined in ScannerInformation.bulk_materials.

  • The detection efficiencies consist of detection bin (crystal) efficiencies, module pair (symmetry group) efficiencies and a calibration factor of 1. Module pairs are grouped into symmetry groups by their class (p1, p2, d, da) with the position p1 / p2 of the first / second module in its panel (transaxial module index mod 2), the transaxial module offset d = (t1 - t2) mod 12 and the axial module offset da = a1 - a2 >= 0 (t, a: transaxial / axial module index, first module = module with the higher index, i.e. never at a lower axial module position). A rotation by one panel maps transaxial module t to t + 2 and an axial shift maps axial module a to a + 1, both keep the class. For modules at the same axial module position (da = 0), a rotation can swap the order of the modules of a pair, which maps class (p1, p2, d, 0) to (p2, p1, 12 - d, 0) with the transposed module pair efficiency matrix values[bin in first module][bin in second module]. For da > 0, the first module is always the one at the higher axial module position, so no symmetry swaps the order (no transposed SGIDs). The SGIDs are ordered by (da, d, p1, p2), i.e. SGID = 14 * da + 2 * (d - 3) + p1, which gives 42 symmetry groups (7 with --modules_per_panel 1 --num_axial_modules 1, one per offset):

    SGID (+ 14 da) 0 1 2 3 4 5 6 7 8 9 10 11 12 13
    class (p1, p2, d) 0,1,3 1,0,3 0,0,4 1,1,4 0,1,5 1,0,5 0,0,6 1,1,6 0,1,7 1,0,7 0,0,8 1,1,8 0,1,9 1,0,9
    transposed SGID (da = 0 only) 13 12 10 11 9 8 6 (symmetric) 7 (symmetric) 5 4 2 3 1 0

    The 36 x 36 SGID LUT consists of 3 x 3 blocks of 12 x 12 (axial module positions of the first / second module):

    second module at axial position 0 1 2
    first module at axial position 0 lower triangle, SGIDs 0-13
    1 full block, SGIDs 14-27 lower triangle, SGIDs 0-13
    2 full block, SGIDs 28-41 full block, SGIDs 14-27 lower triangle, SGIDs 0-13

    The lower triangles of the diagonal blocks (rows: first transaxial module, columns: second transaxial module, .: not in coincidence) are

         0  1  2  3  4  5  6  7  8
     3:  1
     4:  2  0
     5:  5  3  1
     6:  6  4  2  0
     7:  9  7  5  3  1
     8: 10  8  6  4  2  0
     9: 13 11  9  7  5  3  1
    10:  . 12 10  8  6  4  2  0
    11:  .  . 13 11  9  7  5  3  1
    

    and the full off-diagonal blocks contain 14 * da + 2 * (d - 3) + p1 for all transaxial module pairs with a circular distance of at least 3 (also above their diagonal), e.g. for da = 1, first transaxial module 0, second transaxial module 3: d = 9, SGID 14 + 12 + 0 = 26.

  • The efficiencies are non-physical and deliberately exaggerated and structured (--efficiency_model structured, default, see python/efficiencies.py), such that ignoring or misinterpreting them gives clear, recognizable artifacts, and with as few symmetries as possible, such that flipped / swapped indices or transposed matrices change the result:

    • crystal efficiency = module gain (sinusoidal over the transaxial module index x axial module gain 1.0 / 1.71 / 1.65, module 2 x 1.8) x tangential ramp (0.5 ... 1.3) x layer factor (front 1.4, back 0.6) x axial profile (0.96 / 1.16 / 0.36) x 10% jitter, and a dead patch of 3 x 3 crystals in the front layer of module 19 (transaxial module 7 at the central axial module position)
    • module pair efficiency = level of the class (alternating with the transaxial module offset, with opposite phase for odd axial module offsets, different for the two classes of an offset, lower for larger axial module offsets) x a function of the tangential positions of both crystals (i.e. of the radial position of the LOR) x an axial factor (oblique LORs lower) x a strongly non-symmetric layer factor (front -> back 1.6, back -> front 0.4) x 10% jitter
    • --efficiency_model random gives the previous random efficiencies (crystal efficiencies uniform in [0.2, 2.2], x3 / x(1/3) in the first / last module, some dead crystals, random non-symmetric module pair matrices)

Reconstructions of PETSIRD listmode files

The reconstruction is meant as a reference implementation of reading and reconstructing PETSIRD data. It supports multiple module types, energy bins and time blocks, the full detection efficiency model and TOF. It stops with an error for features that would lead to wrong reconstructions:

  • bed or gantry movement time blocks
  • weighted event time blocks
  • different TOF bin edges / TOF resolutions for different module type pairs
  • non-equidistant or asymmetric TOF bins

and warns about information that is ignored:

  • gantry alignment (the image is reconstructed in the PET gantry coordinate system)
  • delayed events, if no randoms correction is used, and dead time time blocks (no dead time correction)
  • single, triple and quadruple events, singles histograms per singles unit (level MODULE), external signals and non-detecting volumes

The time blocks are read with the yardl-generated Python code (about 3 µs per event). If the optional compiled package petsird_fast (prototype, yardl-generated C++ code via libpetsird) is installed, it is used automatically instead, which is about 30x faster end to end with identical results. Both simulator and reconstruction have the option --petsird_backend {auto,petsird,petsird_fast} to choose the backend explicitly (the simulator writes byte-identical files with both).

After the reconstruction, the same visualization of the PETSIRD geometry and the first events is shown on top of the reconstructed image (and saved as my_petsird_file_geometry_and_events_<fingerprint>_<hash>.png).

All files written by the reconstruction script (cached sensitivity images, backprojections and reconstructions) are tagged with a fingerprint of the listmode file (<fingerprint>, computed from the file size and its first and last 4 MiB) and a hash of the reconstruction parameters (<hash>). Re-running a simulation into the same directory therefore never reuses cached files of the previous listmode file. Cache files are written atomically, and a cache file that can not be loaded is recomputed. The events are not cached: they are read from the listmode file in every run.

Time ranges

python 02_reconstruct_petsird.py my_petsird_file.bin --time_range_ms 0 500

only uses the time blocks (events, singles histograms, ...) whose time interval lies within [0, 500] ms. The backprojections, reconstructions and figures are tagged with _t0-500ms. With the oracle randoms correction (--randoms_expectation), the true expected randoms of the selected prompts (over the whole acquisition) are scaled with the fraction of the acquisition time that is selected (the simulated randoms are constant over time).

Detection efficiency factors

python 02_reconstruct_petsird.py my_petsird_file.bin --efficiencies {all,module_pairs,detection_bins,none}

selects which of the encoded detection efficiency factors are used, consistently in the forward model of the events and in the sensitivity image:

mode factor of an event / LOR
all (default) calibration factor x detection bin efficiencies x module pair (SGID) efficiency
module_pairs module pair (SGID) efficiency only
detection_bins detection bin efficiencies only
none 1 (purely geometric sensitivity image)

In all modes, only module pairs in coincidence (SGID >= 0 in the module pair SGID LUT) are used. Reconstructions with only some (or none) of the factors show the artifacts of ignoring the others, e.g. for the simulated (structured) efficiencies: a cold streak from the dead patch (whose LORs are in the sensitivity image but have no events), sector artifacts from the module gains, axial bands from the axial profile, and ring artifacts from the module pair efficiencies. This helps to check whether the encoded efficiencies are interpreted correctly. The reconstructions are tagged with _effs_<mode>.

NON-TOF NAC recon

python 02_reconstruct_petsird.py my_petsird_file.bin --non-tof

TOF NAC recon

python 02_reconstruct_petsird.py my_petsird_file.bin

Creation of a simple 2-class air/water attenuation image

To create a simple 2-class attenuation image, use

python 03_create_two_class_att_img.py my_petsird_file.bin

which uses the TOF backprojection (my_petsird_file_tof_backproj_<fingerprint>_<hash>.nii) created by the TOF NAC recon script above. If several reconstructions with different settings were run, pass the TOF backprojection .nii file of the TOF NAC recon instead. If no --threshold is given, Otsu's method is used for the segmentation. The attenuation image is saved as my_petsird_file_att_img_<fingerprint>_<hash>.nii.

NON-TOF AC recon

python 02_reconstruct_petsird.py my_petsird_file.bin --non-tof --attenuation_image my_att_img.nii

TOF AC recon

python 02_reconstruct_petsird.py my_petsird_file.bin --attenuation_image my_att_img.nii

For data created by the simulator, use the simulated attenuation image (attenuation_image.nii in the output directory) for a quantitatively correct attenuation correction. The 2-class attenuation image created by 03_create_two_class_att_img.py is only an approximation of it.

The attenuation image defines the image grid of the reconstruction (shape, voxel size and position, from its NIfTI affine) unless --img_shape / --voxel_size are given. In that case (or for rotated grids), the attenuation image is resampled onto the reconstruction grid (centered at the scanner iso center) with trilinear interpolation, so an attenuation image on any grid in the scanner coordinate system can be used.

Reconstruction challenge

The phantom uniform_cylinder_text hides a 3-letter word in a uniform cylinder: one letter (cap height 40 mm, 6 mm thick axially, 15% contrast) in each of 3 equally spaced axial sections (z = -14, 0, +14 mm for the default image, about the centers of the 3 axial module positions), the first letter at the lowest z. The letters read along +x and are upright when the transaxial slices are shown with x to the right and y downwards (as in viewer.py).

The contrast is chosen such that the letters are only readable if the detection efficiencies are decoded correctly: reconstructions that ignore the module pair efficiencies or the detection bin efficiencies, or all of them (02 --efficiencies), are dominated by artifacts (rings, sectors, a strong central blob) that hide the letters completely. Mirrored letters or a wrong letter order reveal flipped axes or swapped axial module positions.

Challenge file (20M trues, random fraction 0.2, 25M prompts + 5M delayeds, ~150 MB):

python 01_analytic_petsird_lm_simulator.py --phantom uniform_cylinder_text --num_true_counts 20000000 --random_fraction 0.2

Give participants the listmode file and the attenuation image. With this repository's reconstruction (02 --attenuation_image attenuation_image.nii --randoms_from_singles --num_epochs 2 --num_subsets 10), the letters are readable after a Gaussian post filter of about 4 mm FWHM (box "FWHM [mm]" of the viewer).

Image files

All images (simulator: ground truth, attenuation, sensitivity, LM back projection, histogram MLEM; 02: sensitivity images, back projections, reconstructions; 03: attenuation images; 04: histo-images) are NIfTI-1 files (.nii, float32), written and read with python/image_io.py (nibabel). Arrays that are not images (e.g. prompts_randoms_expectation.npy, one value per prompt, and the estimated singles *_randoms_singles_*.npy) are NumPy files.

Conventions:

  • the NIfTI affine maps the voxel indices (i, j, k) of img[i, j, k] to the center of the voxel in the scanner coordinate system of the PETSIRD file (in mm, the coordinate system of the detecting elements / ADPs): (x, y, z, 1) = affine @ (i, j, k, 1). All grids of this repository are axis-aligned: affine = [[vx, 0, 0, ox], [0, vy, 0, oy], [0, 0, vz, oz], [0, 0, 0, 1]] with the voxel size (vx, vy, vz) and the center (ox, oy, oz) of voxel [0, 0, 0].
  • qform_code = sform_code = 1 ("scanner-based anatomical coordinates"), spatial unit mm. The PETSIRD scanner coordinate system is not a patient coordinate system: the orientation labels (L/R, A/P, S/I) that NIfTI viewers show have no meaning here.
  • units of the values (not stored in the files): attenuation images in 1 / mm, activity (ground truth, reconstructions) in arbitrary units such that the forward model of the simulation (with the sensitivity image of the same grid) gives the expected counts, back projections and histo-images in counts (weighted counts with --efficiency_weighted / --attenuation_image).

Example (Python):

import nibabel as nib
nii = nib.load("data/sim_offcenter_cylinder_4000000_0_petsird_fast/attenuation_image.nii")
img, affine = nii.get_fdata(), nii.affine   # img[i, j, k], voxel center = affine @ (i, j, k, 1)

Randoms correction

python 02_reconstruct_petsird.py my_petsird_file.bin --attenuation_image my_att_img.nii --randoms_from_delayeds ml

(or --randoms_from_singles, see below) estimates the randoms from the delayed coincidences in the PETSIRD file and uses them as additive contamination in the LM OSEM reconstruction (see python/randoms.py and the theory in docs/randoms_estimation.md). The expected randoms of a pair of detection bins (a, b) in coincidence are modeled as s_a * s_b (uniform over the TOF bins), where the singles s are estimated from the fan sums of the delayeds F_a (number of delayeds of detection bin a). The fans (detection bins in coincidence) follow from the module pair SGID LUT of the PETSIRD file. Two estimators are available:

  • ml (default for --randoms_from_delayeds): maximum likelihood estimate (Poisson model of the delayeds), --randoms_ml_iterations (default 10) monotone iterations initialized with the Casey-type estimate
  • casey: Casey-type fan-sum estimate s_a = F_a / sqrt(sum_{b in fan(a)} F_b), which is only exact if all fan sums of the singles are equal (biased by up to 14% for module pairs of the simulated scanner, see tests/study_randoms_estimation.py)

The estimated singles are saved as my_petsird_file_randoms_singles_<method>_<fingerprint>.npy. For simulated data, --randoms_from_singles calculates the randoms from the singles histograms (per detection bin, level ALL). For static scans (constant singles rates, the default --randoms_from_singles static), the singles counts C_a are summed over all time blocks and the randoms are 2 tau C_a C_b / T (acquisition time T): one product per event, like the estimates from the delayeds (about 100x faster than per time block for 100 time blocks). --randoms_from_singles time_blocks uses 2 tau sum_k C_a,k C_b,k / dt_k (singles counts C in time blocks k of duration dt_k), which is also correct for time-varying singles rates (e.g. decay, for which the static estimate is too low). PETSIRD has no field for the coincidence window 2 tau, which is therefore assumed to be the range covered by the TOF bins (true for the simulated data; if TOF bins outside of the coincidence window are discarded, the randoms have to be rescaled accordingly). Only one event and one singles energy bin are supported.

--randoms_expectation prompts_randoms_expectation.npy uses the true expected randoms of all prompts written by the simulator instead ("oracle" randoms correction). Without randoms correction, the reconstruction of data with randoms is biased (a warning is shown). Detection bins without delayeds get zero singles (which is the ML estimate), and the LM OSEM then uses a small eps in the expected counts of all events (only needed for very low numbers of delayeds). Reconstructions without attenuation correction are expected to be biased low (and to show "cupping").

TOF histo-images

python 04_tof_histo_image.py my_petsird_file.bin [--stream {prompts,delayeds}] [--tof_position {center,uniform}]

places every event of the prompt (or delayed) stream at the center of its TOF bin along its LOR (most likely emission position, following the PETSIRD TOF definition) and accumulates them in an image. This is a TOF backprojection with a point-like TOF kernel, useful as a quick look at the data and to check the TOF convention of a file. The image and a figure with three central cuts are saved next to the listmode file (<stem>_tof_histo_image_<stream>_<fingerprint>.nii / .png).

The histo-image is calculated with the TOF listmode back projector of parallelproj (the same as in the reconstruction, with the TOF bins of the file) and a narrow TOF kernel (see python/histo_images.py):

  • --tof_position center (default): point-like kernel at the TOF bin center (emulated by subdividing every TOF bin into narrow bins with the same centers)
  • --tof_position uniform: uniform kernel over the TOF bin (box of one bin width)

Both kernels are convolved with a narrow Gaussian (--kernel_sigma_mm, default half a voxel), because the projector normalizes the kernel over the image planes crossed by the LOR (up to sqrt(3) voxels apart), which a narrower kernel can miss. The image is in counts (every event inside of the image contributes its weight). The TOF bins have to be equidistant and symmetric around 0 (as for the reconstruction). For the 25M prompts of the challenge file (see above), the histo-image takes 4 s (4 CPU cores; previously 10 s with a NumPy implementation), the complete script 7 s including reading the file with petsird_fast; with CuPy arrays the projector runs on a GPU.

The centers of all TOF bins of a LOR are anchored at the LOR midpoint, and for detectors arranged around the scanner axis the midpoints of many LORs coincide (e.g. at the scanner center and on the scanner axis). With point-like kernels, the image therefore shows a spike / lines at these positions. --tof_position uniform reduces them (central voxel / neighborhood 1.45 instead of 1.6 for the challenge file); a remainder is a property of the back projector (LORs through the scanner center all sample the central voxel), as in the TOF backprojection of the reconstruction. A Gaussian post filter of the image (--postfilter_fwhm_mm FWHM) removes it. --attenuation_image att.nii (1 / mm, resampled onto the grid of the histo-image if needed) weights every event with the inverse attenuation factor 1 / exp(-int mu) of its LOR. The histo-image is then approximately the activity times the geometric sensitivity without attenuation (it is not divided by the sensitivity). Non-TOF data are not supported. Options: --efficiency_weighted (weights 1 / efficiency), --time_range_ms, --petsird_backend.

Encoded detection efficiencies

python 05_show_efficiencies.py my_petsird_file.bin [--energy_bin 0] [--fan_bins 0 270]

visualizes the detection efficiencies encoded in any PETSIRD file (only the header is read) and writes a reference table to compare other readers with (all files next to the listmode file, <stem>_efficiencies_<fingerprint>_*):

output content
crystals.png detection bin efficiencies as image module x detecting element (selected energy bin), efficiency 0 marked in red
sgid_lut.png module pair SGID LUT (lower-triangular, white: not in coincidence)
module_pairs.png module pair efficiency matrix values[element of the first module][element of the second module] of every SGID
fans.png total efficiency of all LORs of some detection bins (--fan_bins), as image module x detecting element of the second detection bin
reference.csv probe and random LORs: detection bins, their (module, element, energy) decomposition and ADPs, SGID, detection bin and module pair efficiencies, calibration factor and total efficiency, computed with the official petsird.helpers

All plots are in index space (module and detecting element numbers, as a reader indexes the encoded arrays), which works for any arrangement of the modules; the positions of the detection bins (ADPs) are in reference.csv. To check your own reader, compute the columns of reference.csv for the same LORs and compare: the first differing column shows which step of the decoding is wrong.

For the simulated data (structured efficiency model, detecting element index = 6 * tangential + 3 * layer + axial for the 10 x 2 x 3 elements of a module), correct decoding shows:

  • crystals.png: in every module (row), a period of 6 elements (3 brighter front layer elements followed by 3 darker back layer elements, each with the axial profile medium / high / low) whose brightness increases along the element index (tangential ramp); smoothly varying module rows within each axial module position (sinusoidal gains, module 2 brightest), the axial module positions 1 and 2 (modules 12-35) brighter than position 0; and the dead patch (red) in module 19 at elements 24-26, 30-32 and 36-38
  • sgid_lut.png: the 3 x 3 block structure above: lower triangles with SGIDs 0-13 on the diagonal blocks, with SGIDs alternating between two values along each diagonal; full blocks with SGIDs 14-27 / 28-41 below; blocks with the same axial module offset identical
  • module_pairs.png: a checkerboard of 3 x 3 blocks (front -> back layer blocks much higher than back -> front), different levels between the SGIDs, symmetric matrices for opposite modules at the same axial module position (SGIDs 6 and 7) and transposed matrices for the transposed SGIDs of the table above (only SGIDs 0-13)
  • fans.png: only the modules in coincidence with the module of the detection bin (at all axial module positions), with the same 6-element periodicity and the dead patch

Simulated data from the CI

Every CI run uploads all outputs of the simulation and the reconstructions (the PETSIRD listmode file, ground truth / attenuation / sensitivity images, reconstructions, figures, sim_parameters.json and provenance.json with the commit and package versions) as a workflow artifact (petsird-simulation-<phantom>-<counts>-<commit>, kept for 90 days). They can be downloaded from the "Actions" tab of the repository (requires a GitHub login). Datasets with other phantoms / number of counts can be created by running the CI workflow manually ("Run workflow").

Code structure

The scripts in python/ only parse the command line and call functions of a few flat modules (no installation needed, the scripts import them directly):

module content
scanner.py definition of the simulated scanner (ScannerConfig), converted into the parallelproj geometry (used for simulating) and the PETSIRD ScannerGeometry (written)
phantoms.py activity and attenuation images of the phantoms (PHANTOMS)
efficiencies.py detection efficiency model, converted into the efficiencies of the simulated LORs and the PETSIRD DetectionEfficiencies
simulation.py forward model, histogram to listmode conversion, ordering of the coincidences, PETSIRD header and writing
petsird_reader.py reading and interpreting PETSIRD data (supported features, ADPs, efficiencies, TOF, events)
reconstruction.py image grid, sensitivity image and LM OSEM reconstruction
image_io.py NIfTI image files (grid in the PETSIRD scanner coordinate system), resampling of images onto other grids
histo_images.py TOF histo-images: TOF listmode back projection (parallelproj) with a point-like or uniform TOF kernel
efficiency_plots.py visualization of the encoded detection efficiencies and reference table of decoded LOR efficiencies (05)
randoms.py randoms model (product of singles), fans of the detection bins, Casey-type and ML estimation of the singles from the delayeds, randoms from singles histograms
geometry_plots.py visualization of the PETSIRD geometry and of events
viewer.py interactive 3-axis viewer (incl. a box to apply an isotropic Gaussian filter with a given FWHM in mm)
utils.py small generic helpers (version check, FWHM / sigma, file fingerprint, caching)

Tests

Unit tests (using a tiny scanner, run in a few seconds) are in tests/test_*.py:

python -m pytest

tests/study_randoms_estimation.py OUTPUT_DIR is a (slower) statistical study of the randoms estimators (bias, variance and convergence for many noise realizations).

Consistency checks

tests/check_simulation_and_recon.py checks a simulated PETSIRD file (and its reconstruction outputs, if present) for consistency with the simulator, using only petsird and parallelproj (see the docstring of the script). These checks are run in the CI:

cd python
python 01_analytic_petsird_lm_simulator.py --output_dir ../ci_output --phantom offcenter_cylinder --num_true_counts 200000 --save_lm_backprojection --skip_plots
python 02_reconstruct_petsird.py ../ci_output/simulated_petsird_lm_file.bin --img_shape 55 55 19 --num_epochs 1
python 02_reconstruct_petsird.py ../ci_output/simulated_petsird_lm_file.bin --num_epochs 1 --attenuation_image ../ci_output/attenuation_image.nii --randoms_from_delayeds ml
python 02_reconstruct_petsird.py ../ci_output/simulated_petsird_lm_file.bin --num_epochs 1 --attenuation_image ../ci_output/attenuation_image.nii --randoms_from_singles
cd ..
python tests/check_simulation_and_recon.py ci_output

About

No description, website, or topics provided.

Resources

Contributing

Stars

1 star

Watchers

2 watching

Forks

Releases

Packages

Used by

Contributors

Languages