8 changes: 4 additions & 4 deletions modules/aerodyn/src/AeroDyn.f90
Original file line number Diff line number Diff line change
Expand Up @@ -1412,7 +1412,7 @@ subroutine Init_RotInflow( p, RotInflow, errStat, ErrMsg )
if (Failed()) return
RotInflow%Blade(k)%InflowVel = 0.0_ReKi

if (p%MHK > 0) then
if (p%MHK /= MHK_None) then
call AllocAry( RotInflow%Blade(k)%InflowAcc, 3_IntKi, p%NumBlNds, 'RotInflow%Blade(k)%InflowAcc', ErrStat2, ErrMsg2 )
if (Failed()) return
RotInflow%Blade(k)%InflowAcc = 0.0_ReKi
Expand All @@ -1422,7 +1422,7 @@ subroutine Init_RotInflow( p, RotInflow, errStat, ErrMsg )
call AllocAry( RotInflow%Tower%InflowVel, 3_IntKi, p%NumTwrNds, 'RotInflow%Tower%InflowVel', ErrStat2, ErrMsg2 ) ! could be size zero
if (Failed()) return

if (p%MHK > 0) then
if (p%MHK /= MHK_None) then
call AllocAry( RotInflow%Tower%InflowAcc, 3_IntKi, p%NumTwrNds, 'RotInflow%Tower%InflowAcc', ErrStat2, ErrMsg2 ) ! could be size zero
if (Failed()) return
end if
Expand Down Expand Up @@ -2031,7 +2031,7 @@ subroutine AD_CalcWind_Rotor(t, u, FlowField, p, p_AD, m, RotInflow, StartNode,
if (.not. associated(FlowField)) return ! use the initial (or input) values for these inputs

! If rotor is MHK, add water depth to z coordinate
if (p%MHK > 0) then
if (p%MHK /= MHK_None) then
PosOffset = [0.0_ReKi, 0.0_ReKi, p%WtrDpth]
else
PosOffset = 0.0_ReKi
Expand Down Expand Up @@ -4541,7 +4541,7 @@ SUBROUTINE ValidateInputData( InitInp, InputFileData, NumBl, calcCrvAngle, ErrSt
! .............................
! check tower mesh data:
! .............................
if (InputFileData%TwrPotent /= TwrPotent_none .or. InputFileData%TwrShadow /= TwrShadow_none .or. InputFileData%TwrAero /= TwrAero_none .or. InitInp%MHK > 0) then
if (InputFileData%TwrPotent /= TwrPotent_none .or. InputFileData%TwrShadow /= TwrShadow_none .or. InputFileData%TwrAero /= TwrAero_none .or. InitInp%MHK /= MHK_None) then
do iR = 1,size(NumBl)
if (InputFileData%rotors(iR)%NumTwrNds <= 0) cycle !bjj: this could be removed since the loops here already take into account the number of tower nodes

Expand Down
2 changes: 1 addition & 1 deletion modules/aerodyn/src/AeroDyn_Driver_Subs.f90
Original file line number Diff line number Diff line change
Expand Up @@ -1411,7 +1411,7 @@ subroutine ValidateInputs(dvr, errStat, errMsg)

if (dvr%MHK /= MHK_None .and. dvr%MHK /= MHK_FixedBottom .and. dvr%MHK /= MHK_Floating) call SetErrStat(ErrID_Fatal, 'MHK switch must be 0, 1, or 2.', ErrStat, ErrMsg, RoutineName)

if (dvr%MHK /= MHK_None .and. dvr%SS_InitInp%CompSeaSt == 1 .and. dvr%IW_InitInp%CompInflow /= 1) call SetErrStat( ErrID_Fatal, 'InflowWind must be activated for MHK turbines when SeaState is used.', ErrStat, ErrMsg, RoutineName )
if (dvr%MHK /= MHK_None .and. dvr%SS_InitInp%CompSeaSt == 1 .and. dvr%IW_InitInp%CompInflow == 0 .and. dvr%IW_InitInp%HWindSpeed > 0) call SetErrStat( ErrID_Fatal, 'Steady Wind option in AeroDyn driver cannot be used for MHK turbines with SeaState.', ErrStat, ErrMsg, RoutineName )

if (dvr%MHK == MHK_None .and. dvr%SS_InitInp%CompSeaSt /= 0) call SetErrStat( ErrID_Fatal, 'SeaState cannot be used with wind turbines.', ErrStat, ErrMsg, RoutineName )

Expand Down
9 changes: 5 additions & 4 deletions modules/seastate/src/SeaState_Input.f90
Original file line number Diff line number Diff line change
Expand Up @@ -925,6 +925,11 @@ subroutine SeaStateInput_ProcessInitData( InitInp, p, InputFileData, ErrStat, Er


! CurrMod - Current profile model switch
if ( ( InputFileData%Current%CurrMod /= 0 ) .AND. ( InitInp%MHK /= MHK_None ) ) then
call SetErrStat( ErrID_Fatal,'CurrMod must be set to 0 for an MHK turbine.',ErrStat,ErrMsg,RoutineName)
return
end if

if ( InitInp%hasCurrField ) then
call SetErrStat( ErrID_Warn,'Expecting current field from InflowWind. Setting CurrMod to 0.',ErrStat,ErrMsg,RoutineName)
InputFileData%Current%CurrMod = 0
Expand All @@ -940,10 +945,6 @@ subroutine SeaStateInput_ProcessInitData( InitInp, p, InputFileData, ErrStat, Er
return
end if

! if ( ( InputFileData%Current%CurrMod /= 0 ) .AND. ( InitInp%MHK /= MHK_None ) ) then
! call SetErrStat( ErrID_Fatal,'CurrMod must be set to 0 for an MHK turbine.',ErrStat,ErrMsg,RoutineName)
! return
! end if


if ( InputFileData%Current%CurrMod == 1 ) then ! .TRUE if we have standard current.
Expand Down